Control Wiring Overview; Rj45 Communication Connection; Changing Parameters; Reset Factory Default Settings - Baldor VS1MX Installation & Operating Manual

Ac extreme duty microdrive
Table of Contents

Advertisement

5.2 RJ45 Communication Connection

The RJ45 Data Port can be used as either a RS485 Serial Modbus interface or to connect the optional remote keypad
(VS1ST-RKEY3) and/or copycat loader (VS1ST-CCL).
Serial Modbus networks use the RS485 PIN connection; see Appendix E for the communication protocols. Remote
keypad kits and copycat programmers use the dedicated MXSTbus connection.

5.3 Changing Parameters

To change a parameter value press and hold the
display changes to  indicating parameter 01. Press and release the ENT/PROG key to display the value of this
parameter.
Use the
UP and
once more to store the change. Press and hold the
The display shows  if the drive is stopped or the real-time information (for example speed) if the drive is running.

5.4 Reset Factory Default Settings

To reset factory default parameters, press the
seconds. The display shows  indicating the drive has reset itself to factory default parameters. Press the STOP
button to acknowledge and reset the drive.

5.5 Terminal Control

When delivered, the VS1MX is set to operate in terminal control mode and all parameters (P-xx) have the default values as
indicated in Chapter 7 Parameters. Connect the motor to the drive, checking star/delta connection for the voltage rating.
1. Remove all power from the control.
2. Connect a control switch between the control terminals 1 and 2 ensuring that the contact is open (drive disabled).
3. Connect a potentiometer (1 kΩ min to 10 kΩ max) between terminals 5 and 7, and the wiper to terminal 6.
4. With the potentiometer set to zero, switch on the power supply to the drive. The display will show .
5. Enter motor data from motor nameplate:
P-01 = motor rated voltage
P-02 = motor rated current
P-03 = motor rated frequency
P-04 = motor rated speed
5-2 Control Wiring
Figure 5-2 RJ45 Data Connection
1 No connection
2 No connection
3 0V
4 RS485 - / MXSTbus
5 RS485 + / MXSTbus
6 +24V Keypad
7 RS485 - / Modbus
8 RS485 + / Modbus
For MXSTbus and Modbus,
data format is fixed as:
1 start bit, 8 data bits,
1 stop bit, no parity.
Baudrate and Address
set in P-35
ENT
ENT/PROG key for > 1 second while the drive displays . The
DOWN arrow keys to change to the required value. Press and release the ENT/PROG key
ENT
UP,
ENT/PROG key for > 1 second to return to operational mode.
STOP
DOWN, and
STOP keys simultaneously for > 2
MN762