Symptoms, Diagnoses And Actions - Samsung DV220AEW/XAA Service Manual

Clothes dryer
Hide thumbs Also See for DV220AEW/XAA:
Table of Contents

Advertisement

4-4. SYMPTOMS, DIAGNOSES AND ACTIONS

n The power does not work.
Is the input AC
voltage normal?
Yes
Is the terminal block
connection normal?
Yes
Is the housing
connection normal?
Yes
Is the 6 Pin wire
among the main
sub PCBs in good
condition?
Yes
Is the sub PCB
normal?
Yes
The problem is in the main PCB
assembly. Please replace it.
Set the input AC voltage.
No
(Check AC 120/240V)
Directly connect the terminal block.
(Connect in the order of Live 2, Neutral,
No
Live 1)
Connect the housing.
No
(Check 120V for AC power)
Check the 6 Pin wire.
No
Replace the sub PCB.
No
(Check DC power, signal and key)
Neutral
L2
L1
Earth
120V
240V
Neutral
L2
L1
Earth
Troubleshooting _ 29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv231aewDv231agwDv231aew/xaaDv231agw/xaa

Table of Contents