OPERATION CHECK-2
OUTPUT LEVEL & THERMAL DETECTION
Regarding the power supply system of this unit.
<Function>

1. High-voltage mode

Usually, the power supply supplies high voltage to the power amplifier circuit when the relay (RL6901) is turned On.

2. Low-voltage mode

When as follows, a power supply changes to the state of supplying low voltage when the relay (RL6901) in turned Off.
(1) Excessive output signal is continuously outputted from power amplifier.
(2) Temperature of a heat sink over 80 degrees.
<Purpose>
1. The loss which power amplifier generates is decreased. As a result, the miniaturization of a heat sink is realized.
2. Corresponds to a safety standard.
<Block diagram>
POWER AMP.
THERMAL
SENSOR
THERMAL
R6380
DETECTION
Q6303
<Necessity for a check of operation>
May not notice the fuse (F6901, F6902) broken in the case of repair.
Because the power supply is continuing supplying voltage from the High side of SEC1 at high-voltage mode.
When a power supply circuit changes to low voltage mode, amplifier does not operate.
Therefore, it is very important to check operation of this power supply system containing a fuse.
<Procedure>
[NOTE]
Don't connect speakers or any load.
Don't short speaker terminals.
(1) Set the unit is Multi channel input state.
(2) Set the master volume into the minimum.
(3) Apply sine wave signal to MULTI CHANNEL INPUT (FL+FR+C+SL) terminals.
(4) Connect an oscilloscope to speaker terminal of FL channel.
(5) Adjust master volume so that a speaker output may become distortion about 5%.
(6) Check that the RL6901 and RL6902 are turned Off after about 5 seconds progress.
And the power supply changes to low-voltage mode.
(7) Adjust the master volume so that output voltage may become half.
(8) Check that the RL6901 and RL6902 are turned On after 2 to 3 minutes.
And the power supply returns to high-voltage mode.
+B1
SPEAKER
HIGH
OUT
+/- 63.0 V
VOLTAGE
MODE
LOW
+/- 29.0 V
VOLTAGE
OUTPUT
MODE
LEVEL
DETECTION
-B1
VOLH/
Q7008
THPRO
2
MAIN
MICROPROCESSOR
High-voltage
Low-voltage
RL6901
D6904
D6903
F6901
F6902
RL6902
SEC1H
23
Q6303
HT-R320
SEC1
PRI.
High
Low
Low
High
T901 MAIN
TRANSFORMER

Hide quick links:

Advertisement

Table of Contents
loading