Data Ports; Passthru And Comm Port Baud Rate - McIntosh C1100 Owner's Manual

Controller and tube preamplifier
Hide thumbs Also See for C1100:
Table of Contents

Advertisement

Data Ports

Data Ports Connections between the C1100 and a
McIntosh Source Component allow for basic function
control of the source component using the C1100 sup-
plied Remote Control. By default, all eight Data Ports
are sent the same Data for the selected source. To
dedicate a Data Port for only one source component
(BAL 1 Input will be assigned to Data Port 1) perform
the following Steps:
1. Press the SETUP Push-button to enter the SETUP
MODE. Refer to figure 2, on page 18.
2. Rotate the TRIM Control until "SETUP: Data Port
1, All Data" appears on the Information Display.
Refer to figure 36.
SETUP: DATA PORT 1
All Data
Figure 36
3. Rotate the ADJUST Control until "SETUP: DATA
PORT 1, BAL 1 Data" appears on the Display.
Refer to figure 37.
SETUP: DATA PORT 1
BAL 1 Data
Figure 37
4. To assign additional Data Ports, first rotate the IN-
PUT Control to select the Data Port and then rotate
the ADJUST Control to select the desired Input.
Refer to figure 38.
SETUP: DATA PORT 2
UNBAL 1 Data
Figure 38
5. In a similar manner, assign any additional Data
Ports.
6. Exit the SETUP Mode by pressing the SETUP
Push-button.
22
Passthru
When the C1100 is part of a Home Theater or Multi-
channel Audio System the Right and Left Front Chan-
nels from an Audio/Video Processor or Surround De-
coder can "Passthru" the C1100 and onto its associated
Power Amplifier(s). The Setup Mode allows selection
of the specified C1100 Input to be used for the Right
and Left Front Channels. In the example below, the
Right and Left Front Channels from the Audio/Video
Processsor will be connected to the BALanced 6 Input
Connectors on the C1100. Refer to pages 8 and 9 for
additional connection information.
Notes: 1. The Phono Inputs are not assignable as a
Passthru Input.
2. If Balanced Input 6 is already assigned to a
given Input, it will not appear in the list of
available Inputs.
3. When one of the Unbalanced Inputs is selected
as a Passthru Input, it is advisable to remove it
from the Input List by switching it Off. Refer to
"Input Settings" on page 18.
1. Press the SETUP Push-button to enter the SETUP
MODE. Refer to figure 2, on page 18.
2. Rotate the TRIM Control until "SETUP: Passthru,
Off" appears on the Information Display. Refer to
figure 39.
SETUP:
Passthru
Off
Figure 39
3. Rotate the ADJUST Control to select "BAL 6"
Input. Refer to figure 40.
SETUP:
Passthru
BAL 6
Figure 40
4. Exit the SETUP Mode by pressing the SETUP
Push-button.
Comm Port Baud Rate
The C1100 may be remotely controlled from other
equipment connected to the Rear Panel RS232 Jack.
The speed at which the C1100 communicates (8 bit, no
parity and 1 stop bit) with other equipment is adjust-
able from 9,600 bits per second to 115,200 bits per
second. To change from the default speed of 115,200
bits per second, perform the following steps:
1. Press the SETUP Push-button to enter the SETUP
MODE. Refer to figure 2, on page 18.
2. Rotate the TRIM Control until "SETUP: RS232,
115200 Baud" appears on the Information Dis-
play. Refer to figure 41.
SETUP: RS232
115200 Baud
Figure 41
3. Rotate the ADJUST Control to select the desired
Baud Rate Speed (115200 thru 9600).
4. Exit the SETUP Mode by pressing the SETUP
Push-button.

Advertisement