Fujitsu WPYA100LA Service Manual page 32

Air to water heat pump, monobloc type
Table of Contents

Advertisement

2 5.SENSOR (TEMP.SUCTION) removal
Sensor
Remove the THERMISTOR SPRING.
Remove the SENSOR (TEMP.SUCTION).
2 6.SENSOR (TEMP.DEFROST) removal
Sensor
Remove the COMPRESSOR COVER ① , COVER②, COVER③, and COVER ④. (See chapter 14)
Remove the SENSOR (TEMP.DEFROST) with the holder.
2 7.SENSOR (TEMP.CIRCULAITING WATER OUTGOING) removal
Sensor
Remove the THERMISTOR SPRING.
Remove the SENSOR (TEMP. CIRCULAITING WATER OUTGOING).
Sensor and Holder
-32-
Holder