Thermistor Resistance Chart - Indesit FDEF31111 Service Information

Table of Contents

Advertisement

Indesit
Company
Thermistor - Resistance Chart
Temperature
Resistance
in degrees C
in K Ohms
- 40
24751.661
- 35
17127.169
- 30
12014.762
- 25
8524.305
- 20
6113.811
- 15
4435.437
- 10
3249.216
- 5
2403.515
0
1794.358
+ 5
1351.294
10
1025.870
15
785.018
20
605.252
25
470.000
30
367.480
35
289.186
40
229.014
45
182.485
Service Note:
"C" Column Type Hydraulics Assembly.
The top section of this assembly is
supported from above the tub roof with a
plastic twist cap and seal.
It is necessary to remove the dishwasher
worktop to gain access. Twist the cap
anticlockwise by 90 degrees to release it.
On reassembly MAKE SURE that the
circular thread protrusion on the top of the
assembly moulding locates centrally in the
hole in the tub before refitting the retaining
cap.
Stress or damage to the cap or thread protrusion can occur if it is forced before being correctly located.
Service Manual UK
Temperature
Resistance
in degrees C
in K Ohms
50
146.215
55
117.828
60
95.420
65
77.718
70
63.584
75
52.260
80
43.166
85
35.808
90
29.828
95
24.961
100
20.955
105
17.668
110
14.951
115
12.695
120
10.824
125
9.259
14 of 20
Retaining Cap
and Seal
Thread
protrusion
English

Advertisement

Table of Contents
loading

Table of Contents