troublesHooting
※ R Self-diagnostics check list
LED
F
R
"Flex Zone-Damper-
Heater Error"
FZ-Ice Pipe Heater
Error
Ice Maker(FF)
Function Error
Ice Room-
FAN Error
Panel ↔ Main
Communication Error
FF Ice Duct Heater
Error
FF Ice Bucket Heater
Error
Comp starting Failure
Error
IPM Fanlt Error
Comp Abnormal
current Detection
Error
Motor Locked Over
RPM Error
Comp under voltage
Error
Comp over voltage
Eroor
Item
Trouble contents
Display error when open error is detected
by damper heater : separation of Damper
Heater housing part, contact error,
disconnection, short circuit.
The error occurs when there is a wire
connector slip-out of the Water Supply
Pipe Heater, a contact error or a
breakage in the wiring.
Display error when open error is detected
by Heater : separation of Ice Pipe Heater
housing part, contact error, disconnection,
short circuit.
Display error during operation of
applicable fan motor : Feed back signal
line contact error rnotor wire separation
motor error.
Display pc - Er in the panel with alarm :
MICOM MAIN ↔ PANEL communication
error.
The Error will be displayed when the Ice
Duct Heater is detected as being open
due to the followings.
- Ice Maker Duct Heater Connector Slip-
Out, Contact Defect or Wire-Breakage
The Error will be displayed when the Ice
Bucket Heater is detected as being open
due to the followings.
Ice Bucket Heater Connector Slip-Out,
Contact Defect or Wire-Breakage.
When the Compressor fails starting
When there is a IPM Fault error
When ther is abnormal crrunt detected at
the Compressor
When there is a Compressor restriction
error
When there is a low voltage error
When there is a over voltage error
F
After separating MAIN PCB CN77 wire from
PCB, resistance value between Black ↔ Brown
wire shall be 135 ohm± 7%.
0 ohm : heater short, ∞ Ohm : wire / bimetal
Open.
When measuring the resistance of the Main
PCB CN79 Yellow-Pink wires, it should be
within 102Ω ±7%.
0Ω : heater short, ∞Ω : Check for Wire Open
or Connector Slip-out
After changing the Ice Maker(R), plug the
refrigerator power code again, and check the
operation.
When measuring the voltage between the
Main PCB CN76-"5" ↔ CN76-"1", it should read
between 7.0V~12V.
Actually, If there is not a problem, it is desirable
to replace Main and Panel PCB With the
oscilloscope after a cable problem confirming.
The resistance between CN79 ORG and CN51
BRN on the Main PCB shall be within 135Ω ±
7%. And, when the resistance reads 0Ω or ∞
Ω, check the followings.
0Ω : Heater Short
∞Ω : Wire-Breakage or Wire Slip-Out
The resistance between CN79 ORG and BRN
on the Main PCB shall be within 135Ω ±7%.
And, when the resistance reads 0Ω or ∞Ω,
check the followings.
0Ω : Heater Short
∞Ω : Wire-Breakage or Wire Slip-Out
Check if there is a short between compressor
terminals. Check IPM Voltage [Under 13.5V]
Check if there is a short between IPM Pins
[#1~33]
Check the Compressor and the Cycle
Check the Compressor connections
Check the voltage of Resistance of R308
[0.09Ohm] Check the Compressor and the
Cycle
Check the voltage of Resistance of R308
[Short/Open] Check the voltage of both of
C103 terminals [Unstable Voltage] Check the
Compressor and the Cycle
Check the voltage of Resistance of R513 [Short/
Open]
Check the voltage of Resistance of R501, R505,
R509 [Short/Open]
R