Samsung RF263BEAE** Service Manual page 55

French door type
Hide thumbs Also See for RF263BEAE**:
Table of Contents

Advertisement

※ R Self-diagnostics check list
LED
F
R
FZ-Sensor Error
FF-Sensor Error
FZ-DEF-Sensor
Error
FF-DEF-Sensor
Error
Ambient-Sensor
Error
PANTRY-Sensor
Error
Ice Maker(F) Sensor
Error
Humidity-Sensor
Error
Ice Maker(FF) Sensor
Error
Ice Room Sensor
Error
FZ-FAN Error
FF-FAN Error
C-FAN Error
FZ-DEF Error
FF-DEF Error
Ice Maker(FZ)
Function Error
Item
Trouble contents
Display error : separation of sensor
housing part, contact error, disconnection,
short circuit.
Display error of detecting temperature of
sensor : more than 149℉(+65°C) or less
than -58℉(-50°C)
Display error : separation of sensor
housing part, contact error, disconnection,
short circuit Display error of detecting
temperature of sensor: more than 149℉
(+65°C) or less than -58℉(-50°C)
Separation of sensor housing part,
contact error, disconnection, short circuit
Display error : separation of sensor
housing part, contact error, disconnection,
short circuit.
Display error of detecting temperature of
sensor : more than 149℉(+65°C) or less
than -58℉(-50°C)
Display error during operation of
applicable fan motor : Feed back signal
line contact error, motor wire separation,
motor error
Display error during operation of
applicable fan motor : Feed back signal
line contact error, motor wire separation,
motor error
Display error during operation of
applicable fan motor : Feed back signal
line contact error, motor wire separation,
motor error
Separation of freezer compartment
defrost heater housing part, contact
error, disconnection, short circuit or
temperature fuse error. Display error :
the defrosting does not finish though
freezer compartment defrost is heating
continuously for more than 80 minutes.
Separation of fresh food compartment
defrost heater housing part, contact
error, disconnection, short circuit or
temperature fuse error. Display error :
the defrosting does not finish though
fresh food compartment defrost is heating
continuously for more than 80 minutes.
When the Freezer Ice Maker error occurs
more than 3 times, the error will be
displayed.
When measuring the voltage between the Main
PCB CN30-"4" ↔ CN76-"1", it should read
between 4.5V~1.0V.
When measuring the voltage between the Main
PCB CN30-"5" ↔ CN76-"1", it should read
between 4.5V~1.0V.
The voltage of MAIN PCB CN30- "5"↔ N76-"1":
shall be between 4.5V~1.0V
When measuring the voltage between the Main
PCB CN30-"8" ↔ CN76-"1", it should read
between 4.5V~1.0V.
The voltage of MAIN PCB CN78- "8"↔ CN78-"
12": shall be between 4.5V~1.0V
The voltage of MAIN PCB CN78- "9"↔ CN76-"
1": shall be between 4.5V~1.0V
The Voltage of MAIN PCB CN90 #8<->#9: Shall
be between 4.5v ~ 1.0v
When measuring the voltage between the Main
PCB CN30-"3" ↔ CN76-"1", it should read
between 4.5V~1.0V.
The voltage of MAIN PCB CN90- "1"↔ CN90-"
7": shall be between 4.5V~1.0V
When measuring the voltage between the Main
PCB CN78-"10" ↔ CN78-"12", it should read
between 4.5V~1.0V.
The voltage of MAIN PCB CN76- "3"(Yellow) ↔
CN76-"1"(Gray): shall be between 7V~12V
The voltage of MAIN PCB CN76- "4"(Orange)
↔ CN76-"1"(Gray): shall be between 7V~12V
The voltage of MAIN PCB CN76- "5"(Sky-blue)
↔ CN76-"1"(Gray): shall be between 7V~12V
After separating MAIN PCB CN70 wire from
PCB, resistance value between CN70 Brown
↔ CN70 Gray shall be 63(230) ohm ±
7%.(Resistance value is varied by input power)
0 ohm : heater short, ∞ ohm : wire/bimetal
open (Must power off)
After separating MAIN PCB CN70 wire from
PCB, resistance value between CN70 White
↔ CN70 Gray shall be 120(440) ohm±
7%.(Resistanc e value is varied by input power)
0 ohm : heater short, ∞ ohm : wire/bimetal
open (Must power off)
After replacing the Ice Maker, check if it