Verifying Port Redundancy Auto-Recovery; Configuring Data Processing Card Availability - Cisco ASR 5500 Administration Manual

Asr 5500 system administration guide, staros release 19
Table of Contents

Advertisement

System Settings

Verifying Port Redundancy Auto-Recovery

Verify port information by entering the following command
show port info slot#/port#
slot# is the chassis slot number of the MIO/UMIO card on which the physical port resides.
port# is the physical port on the MIO/UMIO.
The following shows a sample output of this command for port 1 on the MIO/UMIO in slot 5:
[local]
Port: 5/1
Port Type
Role
Description
Redundancy Mode
Redundant With
Preferred Port
Physical ifIndex
Administrative State
Configured Duplex
Configured Speed
Configured Flow Control : Enabled
Interface MAC Address
Fixed MAC Address
Link State
Link Duplex
Link Speed
Flow Control
Link Aggregation Group
Logical ifIndex
Operational State

Configuring Data Processing Card Availability

As discussed in the Understanding the System Boot Process section of Understanding System Operation and
Configuration, when the system initially boots up, all installed DPC/UDPCsor DPC2/UDPC2s are placed
into standby mode. You must activate some of these cards in order to configure and use them for session
processing. One DPC/UDPC or DPC2/UDPC2 may remain in standby mode for redundancy.
This section describes how to activate DPC/UDPCs or DPC2/UDPC2s and specify their redundancy.
Important
Enter the following command to check the operational status of all DPC types:
show card table
This command lists the DPC types installed in the system by their slot number, their operational status, and
whether or not the card is a single point of failure (SPOF).
Use the following example to configure DPC/UDPC or DPC2/UDPC2 availability:
configure
card slot#
host_name
# show port info 5/1
: 1000 Ethernet
: Management Port
: (None Set)
: Port Mode
: 6/1
: Non-Revertive
: 83951616
: Enabled
: Auto
: Auto
:
:
: Up
: Full
: 1000 Mb
: Disabled
: None
: 83951617
: Up, Active
Refer to the ASR 5500 Installation Guide for information about system hardware configurations and
redundancy.
mode { active | standby }
end
02-05-47-B8-2F-41
02-05-47-B8-2F-41
ASR 5500 System Administration Guide, StarOS Release 19
Configuring Data Processing Card Availability
53

Advertisement