SPECIFICATIONS

2
Indoor model
Function
Power supply
Capacity
Air flow (High/Low)
Power outlet
Running current
Power input Rated frequency
Auxiliary heater
Power factor
1
Fan motor current
Model
Winding
resistance (at20:)
Dimensions W H D
Weight
Air direction
Sound level (High/Low)
Fan speed regulator
Thermistor RT11 (at 25:)
Thermistor RT12 (at 25:)
Thermistor RT13 (at 25:)
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor
Outdoor D.B. 35: W.B. 24:
Heating : Indoor
Outdoor D.B. 7:
Refrigerant piping length (one way): 5m
1 Measured under rated operating frequency.
Specifications and rating conditions of main electric parts
INDOOR UNIT
Item
Indoor fan capacitor
Fuse
Varistor
Terminal block
Indoor fan motor thermal fuse
K /h
A
1
A
W
A(kW)
%
1
A
mm
kg
dB(A)
kΩ
kΩ
kΩ
D.B. 27: W.B. 19:
D.B. 20: W.B. 5:
W.B. 6:
Model
(C)
(FUSE)
(ZNR)
(TB)
Cooling
WHT-BLK : 261
SEZ-KC25VA.W
TO OUTDOOR UNIT : 3P TO WIRED REMOTE CONTROLLER : 2P
4
SEZ-KC25VA.W
Heating
Single phase
230V , 50Hz
474/288
10
0.45
60
97
0.28
CRC4417BB
BLK-BLU : 475
YLW-BRN : 294
790 225 550
19
1
36/25
2
10
10
10
1.5+ 440V
250V 6.3A
ERZV10D471
135:i5: