MAINTENANCE

Air Filter

Level 1.
Parts Required:
1.
Close choke (COLD START [
position). This prevents dirt from
entering the carburetor throat
when the air filter is removed.
Brush accumulated dirt from air
cleaner area.
2.
Remove air filter cover (A).
Brush dirt from inside cover.
3.
Remove air filter (B) and lightly
brush debris from filter. Replace
filter if it is damaged, fuel
soaked, very dirty, or the rubber
sealing edges are deformed.
4.
If filter can be reused, be certain it:
• Fits tightly in the air filter cavity
• Is installed with the original side out
5.
Install air filter cover.

Fuel Filter

Level 1.
Parts Required:
Fuel is VERY flammable. Use extreme care when mixing, storing or
handling, or serious personal injury may result.
1.
Use a clean rag to remove loose
dirt from around fuel cap and
empty fuel tank.
2.
Pull the fuel filter (B) from the fuel
tank.
3.
Remove the filter from the line and
install the new filter.
28
TM
REPOWER
TUNE UP KIT.
]
TM
REPOWER
TUNE UP KIT.