Cooling Cycle Heavy Repair - LG GR-B197GVQ Service Manual

Hide thumbs Also See for GR-B197GVQ:
Table of Contents

Advertisement

3.
Cooling Cycle Heavy Repair
3-1. The
Heavy Repair
Standards for
Refrigerator
with R134a
Refrigerant
NOTE)
Please
contact
Songso
company
on
+82-53-554-2067 if you have
inquiry
on
heavy repair special facility.
TROUBLE DIAGNOSIS
-93-
NO.
Items
Unit
Standards
Purposes
Remarks
1
Pipe
and
piping
Min.
Pipe:within
1
hour.
To
protect
The
opening
time should be reduced
to
a
system
opening
time.
Comp:within
Moisture
half of the standards
during
rain and
10 minutes.
Penetration.
rainy
seasons
(the penetration
of
water
Drier:within
into the
pipe
is
dangerous).
20 minutes.
2
Welding.
Nitrogen
Weld under
To
protect
-
Refer
to
repair
note
in each
part.
Pressure.
Nitrogen
oxide scale
-
R134a
refrigerant
is
more
susceptible
to
atmosphere
formation.
leaks than R12 and
requires
more care
(N2
pressure:
during welding.
0.1~0.2
kg/cm
2
)
-
Do
not
apply
force
to
pipes
before and
after
welding
to
protect
pipe
from
cracking.
3N
2
sealed
parts.
Confirm N2 Confirm air
leaking
To
protect
-
In
case
of
evaporator parts,
if it doesn't
leak.
sounds when
moisture
make noise when
removing bushing
removing bushing
penetration.
cap blow
dry
air
or
N2 gas for
more
cap.
than
1 min
use
the
parts.
Sound:usable
No sound:not usable
4
Refrigeration
Evacuation
Min.
More than
To
remove
Cycle.
time
40 minutes.
moisture.
Vacuum
Torr
Below 0.03
(ref)
Note:Only applicable
to
the model
degree
equipped
with
reverse
flow
protect
plate.
Vacuum
EA
High
and low
Vaccum
efficiency
can
be
improved by
Pressure sides
are
operating
compressor
during
evacuation.
evacuated
at
the
same
time for
models above
200L
Vacuum
EA
Use R134a
To
protect
The
bushing pipes
for R12
refrigerant
shall
piping
exclusive
mixing
of
be melted when
they
are
used for R134a
manifold.
mineral and
refrigerant
causes
of leak.
ester
oils.
Pipe
EA
Use R134a
To
protect
coupler
cxclusive.
R12 Refri-
gerant
mixing.
Outlet
R134a exclusive.
˝
(Socket)
Plug
R134a exclusive
˝
5
Refrigerant weighing.
EA
Use R134a
Do
not
mix
-
Do
not
weigh
the
refrigerant
at too
hot
or
exclusively.
with R12
too
cold
an
area.(25°C
is
adequate.)
Weighing
refrigerant.
-
Use copper
charging
cannister.
allowance: ±5 g
Socket:2SV
Plug:
2PV R134a
Note:Winter: -5 g
Do
not
mix
Note:Do
not
burn
O-ring (bushing) during
Summer: +5 g
refrigeromts.
welding.
6
Drier
replacement.
-Use R134a
exclusively
To
remove
for R134a
refrigerator
the moisture
-Use R12
exclusively
from
pipe.
for R12
refrigerator
-Replace
drier whenever
repairing refrigerator
cycle piping.
7
Leak check.
-Do
not
use
soapy
Detect
-Check oil leak
at
refrigerant
leak
area.
water
for check.
refrigerant
Use electronic leak detector if oil leak is
it may be sucked
leak
area.
not
found.
into the
pipe.
-The electronic leak detector is very
sensitive
to
halogen
gas in the air. It also
can
detect R141b in urethane. Please
practice,
the
refore,
many times before
use.