coPY FunctIon

Use the copy function to copy settings from 1 master amplifier to 1 slave
amplifier. The models must be identical!
The following settings can be copied: threshold value, output operation,
timer operation, timer delay, emission level, shift, external input, threshold
value storage, ECO, invert digital display, and threshold value margin.
Procedure, set copy function
In Pro MoDE of the master amplifier, turn on the setting copy function by
pressing <MODE> until
ready state.
1. Turn off the master amplifier.
2. Connect the master amplifier and the slave amplifier as shown.
Master
(Brown) +V
(Black) Input
(White) External input
(Blue) 0V
Slave
(Brown) +V
(Black) Input
(White) External input
(Blue) 0V
3. Turn on the master amplifier and the slave amplifier at the same time
(see note)!
4. On the master amplifier,
in red. Copying starts.
5. When copying is completed,
amplifier and the same 4-digit code as the master amplifier is displayed
in red.
6. Turn off the power of the master amplifier and the slave amplifier and
disconnect the wire.
To copy settings to another amplifier, repeat steps 3 to 7.
*
If the power is not turned on at the same time, the setting con-
tents may not be copied.
To cancel the setting copy function of the master amplifier
1. While the slave side amplifier is disconnected, turn on the power of the
master side amplifier.
2. Press <MODE> for 2s.
is displayed. The sensor is in the copy
Color code of cable with connector
Power supply
is displayed in green and the 4-digit code
is displayed in green on the slave
12

QuIcK sEttInG FunctIon

Simply by selecting a quick setting number, which are listed in the table at
the end of this section, you can set: output operation, emission level, timer,
and emission frequency.
RUN mode
+
Press for 2s
*
During the setting process, press <MODE> for 2s to cancel and
return to run mode.
*
When the present setting does not correspond to a quick
setting number,
changed.
Table of quick setting numbers
Output
No.
FX-100□-Z modified
operation
Level
-00-
D-on
3
-01-
D-on
2
-02-
D-on
3
-03-
D-on
2
-04-
D-on
3
-05-
D-on
2
-06-
D-on
3
-07-
D-on
2
-08-
D-on
3
-09-
D-on
2
-10-
L-on
2
-11-
L-on
3
-12-
L-on
2
-13-
L-on
3
-14-
L-on
2
-15-
L-on
3
-16-
L-on
2
-17-
L-on
3
-18-
L-on
2
-19-
L-on
3
6
Automatic
Quick setting number
,
Select quick setting number
Emission frequency setting
,
Select emission frequency
is displayed and the set content is not
Emission amount setting
FX-100□-Z conventio-
nal ON/OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Timer
non
non
ofd 10ms
ofd 10ms
ofd 40ms
ofd 40ms
ond 10ms
ond 10ms
ond 40ms
ond 40ms
ond 40ms
ond 40ms
ond 10ms
ond 10ms
ofd 40ms
ofd 40ms
ofd 10ms
ofd 10ms
non
non

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meuen-fx100z

Table of Contents