Simple Way Of H.v. Inverter/Magnetron Troubleshooting; V.inverter Board Main Parts List (F606Y8M00Ap) - Panasonic NN-SD997S Service Manual

Hide thumbs Also See for NN-SD997S:
Table of Contents

Advertisement

4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON
TROUBLESHOOTING
Purpose:
Simple way (3/37 seconds rule) of identifying whether it's Magnetron, Inverter, or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Shut off in 37 seconds
1. Between 0.5A and 1.0A.
after "Start".
2. Between 1.0A and 2.0A.
Shut off in 3 seconds
1. Less than 0.5A
after "Start"
5 H.V.INVERTER BOARD MAIN PARTS LIST
(F606Y8M00AP)
Ref. No.
Part No.
DB701
B0FBBS000001
L701
F50206G00AP
Q701
B1JAGV000015
T701
A609A8M00AP
C701
ECWF5284N300
C702
ECWF2455N644
Ammeter reading is:
Check and repair open magnetron circuit Open magnetron wiring between Inverter
Check continuity of D702 in Inverter PCB.
1. D702 shorted
2. D702 is OK
Check open circuit: Latch Switch, DPC,
Power Relay and CN701
Part Name & Description
BRIDGE DIODE
CHOKE COIL
TRANSISTOR SI
H.V. TRANSFORMER
CAPACITOR
CAPACITOR
NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S
To do:
Pcs/Set
1
20A, 600V
1
1
1000V
1
(INCLUDING D701,D702,C706,C707)
1
0.28µF/500V
1
4.5µF/250V
9
Remedy:
and magnetron terminal.
Replace H.V.Inverter(F606Y8M00AP)
Replace magnetron
Replace
defective
component(s),
correct switch, cables and connectors.
Remarks
or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nn-sd987sNn-sd967sNn-sn977sNn-sn957sNn-sn947s

Table of Contents