SPLIT-TYPE AIR CONDITIONER Basic : AQV18VBA AQV24VBA Model : AQV18VBC AQV24VBC Model Code : AQV18VBCN AQV18VBCX AQV24VBCN AQV24VBCX AIR CONDITIONER THE FEATURE OF PRODUCT High Energy Efficiency BLDC Air Conditioner Luxury Half Mirror Design Mode Mode can help you sleep quickly and soundly and wake up refreshed.
5-3 Ass’y Control In ..........................5-4 Ass’y Control Out ..........................16. Electrical Parts List ........................17. Wiring Diagram ..........................7-1 Indoor Unit ............................7-2 Outdoor Unit ............................ 18. Schematic Diagram ........................8-1 Indoor Unit ............................8-2 Outdoor Unit ............................ Samsung Electronics...
Page 3
14-2 Low Refrigerant Pressure Distribution 14-2 ..................14-3 Pressure & Capacity mark 14-3 ......................14-4 Q & A for Non-trouble 14-4 ........................14-5 Cleaning/Filter Change 14-7 ......................... 14-6 Installation 14-9 ............................14-7 Installation Diagram of Indoor Unit and Outdoor Unit 14-10 ............Samsung Electronics...
Do not place a cloth or other materials over it. Remove the batteries if you don’t use the remote control for a long time. (If applicable) Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics...
Young children or infirm persons should be always supervised when they use the air conditioner. Max current is measured according to IEC standard for safety. Current is measured according to ISO standard for energy efficiency. Samsung Electronics...
Mode can help you sleep quickly and soundly and wake up refreshed. Mode The Micro Plasma Ion mode creates strong purified zone in your room. Silence Mode When you use the “Silence Mode”, you can experience extremely quiet operation of your air conditioner. Samsung Electronics...
Outdoor Unit 58dB↓ 60dB↓ Silver Nano Evaporator Silver Nano Evaporator Filter Anti Allergy Filter Anti Allergy Filter Air Purifying System Deodorizing Fiter Deodorizing Fiter Micro Plasma Ion MPI Mode MPI Mode Indoor Display Digital i Display Digital i Display Samsung Electronics...
• Because the Test Mode operate the cool mode by force not related to the set temperature / indoor temperature, check whether each subordinate is operated normally or not after completing installation and must turn off the power of the air conditioner. Samsung Electronics...
Indoor Fan Motor Abnormal Operation FAN Error Holding for 15 sec. at less than 450rpm 1min. Time out Communication MPI Error All Lamps Blink EEPROM Error All Lamps Blink Option Error Option Not Set up, Option Data Error Samsung Electronics...
● ○ GAS Leak error ● ● ◎ AC Line Zero Cross Signal out ● ● ● Power ON reset(1sec) ◎ ○ ○ Capacity miss match ● : LED ON, ○ : LED OFF, ◎ : LED BLINK Samsung Electronics...
Setting is not required if you must Every time you push the button, the display panel reads a value which has a default. . . . repeatedly. Samsung Electronics...
Page 16
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model. Samsung Electronics...
2) Please open the front grille. 3) Please detach link grilles from main frame. 4) To detach front grille from main frame, please catches finger stop 5) Please loosen clamping screw and detach the terminal cover. 6) Please take out filter to downward. Samsung Electronics...
Page 20
2EA at the front of the panel front. 9) Loosen the screw of the ASSY DISPLAY. 10) Please separate Linked connector from the assy display. 11) Unlock 2 hooks between panel front and try drain to seperate panel front. Samsung Electronics...
Page 21
12) Unlock 2 hooks between panel front and back body. TRAY DRAIN 1) Please detach stepping motor wire. 2) Please pull tray drain and separate from back body. evap 1) Loosen the ground wire screw. 2) Detach the temperature sensor. 3) Detach the holder pipe. Samsung Electronics...
5) Loosen 1EA screw, right of holder motor. 6) Detach the heat exchanger from indoor unit. MAIN PCB 1) Loosen 4EA screws of holder. 2) Detach Link wires of indoor, outdoor unit and fan motor. 3) Detach assy control from indoor unit. Samsung Electronics...
Page 23
Disassembly and Reassembly Parts Procedure Remark Fan Motor 1) Loosen 2EA screws of holder motor and & Detach the holder. Cross Fan 2) Loosen a screw and detach the cross fan. 3) Detach the holder bearing and motor. Samsung Electronics...
Page 24
1) Loosen 1 fixing screw(CCW) of the Cover- Control and detach the Cover Control. 2) Loosen fixing screws(CCW) and detach the Cabinet-Upper. 3) Loosen 1 screw(CCW) fixed to assemble Control Box with Cabinet-Side RH. 4) Loosen 6 fixing screws(CCW) and detach the Cabinet-Side RH. Samsung Electronics...
Page 25
Disassembly and Reassembly Parts Procedure Remark 6) Loosen fixing screws(CCW) of the Cabinet Front. 5) Loosen 2 screws(CCW) fixed on the Guide Condenser. Samsung Electronics...
Page 26
Motor 2) Detach the Fan Propeller. 3) Loosen 4 fixing screws(CCW) to detach the Motor. 4) Disconnect the wire between Ass’y Control Out and Motor. 5) Loosen 2 fixing screws(CCW) and detach the Bracket Motor. Samsung Electronics...
Page 27
3) Disassemble the pipes in both inlet and outlet with welding torck. Before you disassemble the pipes and Condenser, be sure that there should be no refrigerant remained in the unit. 1) Loosen fixing screw(CCW) and detach the Heat Exchanger 4-10 Samsung Electronics...
Page 28
Procedure Remark Compressor 1) Disassemble the Felt Comp Sound. 2) Loosen the fixing nut(CCW) and detach the Compressor Lead Wire. 3) Loosen the 3 bolts(CCW) at the bottom of Compressor like the picture on the right side. Samsung Electronics 4-11...
9-1-1 Indoor Unit SMPS PART BUZZER PART INDOOR FAN CONTROL SUB PCB CONNECTOR ZERO CROSSING PART DISPLAY PART STEP MOTOR & ION INDOOR TEMPERATURE SENSOR MPI PART HUMID PART This Document can not be used without Samsung’s authorization. Samsung Electronics...
Page 54
Circuit Descriptions Circuit Descriptions 9-1-2 Outdoor Unit TEMPERATURE SENSOR & EEV SMPS INVERTER This Document can not be used without Samsung’s authorization. Samsung Electronics...
9-2 Refrigerating Cycle Diagram Indoor Unit Outdoor Unit 2 way valve Expansion valve Liquid side Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Cross Fan Gas side 4 way valve 3 way valve Cooling Compressor Heating Gas Leak Check Point Samsung Electronics...
10. PCB Diagram 10-1 Indoor PCB The red number connecter is not used. Power Temperature Sensor Motor RPM Feedback Auto Grill Remocon Module HVPS(High voltage Generator) Humidity Sensor BLADE-H Step Motor Anions Display Indoor Fan Motor Samsung Electronics 10-1...
10-2 Outdoor PCB The red number connecter is not used. Power N COND/OLP Temperature Sensor Power L DIS/OUT Temperature Sensor BLDC FAN EEV Connector AC FAN Comp. Connector Wire Communication 485 Reactor Connector Wire 10-2 Samsung Electronics...
The design and shape are subject to change according to the model. Air Inlet Room Temperature sensor Power(On/Off) button Air filter Airflow blade (under the panel) (outlet) MPI(Micro Plasma Ion) mode indicator Timer/Good Morning Auto cleaning indicator mode indicator Set temperature & Operation indicator room temperature Samsung Electronics 11-1...
Page 59
Operating Instructions 11-1-2 Outdoor Unit Air Inlet (Rear) Air Outlet Connection Valve 11-2 Samsung Electronics...
Auto Low Medium High Heat Mode Press the button on the remote control until Heat is displayed. Press the button to select the fan speed until the required setting is displayed. Auto Low Medium High 11-4 Samsung Electronics...
Page 62
MPI Mode The air conditioner starts up in MPI-Auto mode automatically. The MPI mode also runs when the air conditioner is turned on. By pressing the button again, the MPI mode is canceled. Samsung Electronics 11-5...
The compressor operates in a reverse cycle to remove Indoor fan and outdoor fan stop operation intermittently exterior ice in a HEAT mode, and indoor fan and outdoor in a HEAT mode. fan do not operate intermittently for within 20% of the total heater operation 12-1 Samsung Electronics...
Replace fuse FUSE(F701) : T3.15[A]/250[V] Check the output of SMPS on the control board. Input power: AC230±15%[V] PCB should be replaced IC02 Input: DC12[V] IC02 output: DC5[V] Check the setting temperature Samsung Electronics 12-2...
Page 65
Is there no error at the insertion of PCB? Exchange the PCB. Exchange the PCB. Are the BLDC FAN Wire Is the +,- of C102 short? 1 and 3 short? Exchange the PCB. Exchange the BLDC FAN. Normal Operation Exit 12-3 Samsung Electronics...
Page 66
Voltage at pin #30~#34 of micom (IC04) Micom (IC04) is faulty. change?(Squarewave) Voltage at Driver IC05/06 (ULN2003A) is faulty. pin #2 ~ #5 of CN61(motor connector) change?(Squarewave) Up/Down louver motor is faulty. Samsung Electronics 12-4...
Page 67
Pull out the power cord and during the operation?(Square-Wave) execute the following step after 30 seconds. Disassemble the BLDC FAN Wire. Is the short between Exchange the PCB. the BLDC FAN Wires? Exchange the BLDC FAN MOTOR. Exchange the PCB. 12-5 Samsung Electronics...
Page 68
Pull out the power cord and exchange the PCB from the case after 30 seconds. Is the assembly of Micom and Exchange the PCB. peripheral circuit part good? Check again after assembly of PCB. Samsung Electronics 12-6...
Page 69
4 way valve coil. Dose the voltage of AC 220V Exchange apply to the connector of 4 way the outdoor PCB. valve coil during the operation? Go to the next page 4 way valve main body error 12-7 Samsung Electronics...
Page 70
Connect the connector. correctly? Check the resistance value Outdoor fan error of outdoor fan. Dose the voltage of DC300V apply to the connector of outdoor Check the motor wire. fan during the operation of outdoor unit? Outdoor PCB error Samsung Electronics 12-8...
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 18.2K? Exchange the PCB. Exchange the PCB. Normal operation Exit 400.0 350.0 300.0 250.0 200.0 150.0 100.0 50.0 12-9 Samsung Electronics...
Page 72
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 24K? Exchange the PCB. Exchange the PCB. Normal operation Exit 600.0 500.0 400.0 300.0 200.0 100.0 Samsung Electronics 12-10...
Page 73
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 18.2K? Exchange the PCB. Exchange the PCB. Normal operation Exit 400.0 350.0 300.0 250.0 200.0 150.0 100.0 50.0 12-11 Samsung Electronics...
Page 74
4) Is the resistance value of sensor connection pull_up correct? 2. Troubleshooting procedure Remove the Fan lock. Isn't the Fan locked? Is the connector connected correctly? Connect the connector. Is the color of Fan wire matched correctly? Exchange the Fan. Exchange the PCB. Normal operation Exit Samsung Electronics 12-12...
Page 75
1, 2 correct after power supply? Is the capacitor(C101, C102, C103) Connect the connector. for DC-Link assembled in accordance the specification? Are R113, R114, R115 470kohm? Exchange the PCB. Is R116 14.3kohm? Exchange the Fan. Exchange the PCB. Normal operation Exit 12-13 Samsung Electronics...
Page 76
Is the position of temperature sensor Correct the sensor position or and the sensing value normal? exchange the sensor. Is the connection cable for Correct the cable connection. the compressor and power terminal normal? Exchange the PCB. Samsung Electronics 12-14...
Correct the wrong wiring. and communication cable error? Is the connection of Correct the connection of communication cable normal? communication cable. Is it the outdoor Exchange the indoor/outdoor unit PCB. 2 Micom(Inverter + Main) model? Exchange the outdoor unit PCB. 12-15 Samsung Electronics...
Page 78
Exchange the compressor. compressor (uv, vw, wu) normal? Is the compressor body and Exchange the compressor. interphase resistance insulated? Is the connection cable for the Correct the cable connection. compressor and power terminal normal? Exchange the PCB. Samsung Electronics 12-16...
Page 79
Exchange the compressor. compressor (uv, vw, wu) normal? Is the compressor body and Exchange the compressor. interphase resistance insulated? Is the connection cable for the Correct the cable connection. compressor and power terminal normal? Exchange the PCB. 12-17 Samsung Electronics...
Page 80
Is the resistance for the Exchange the PCB. detection of DC Link voltage normal? Is the resistance value of Exchange the PCB. DC Link discharge normal? Is the reactor insulation damaged? Exchange the PCB. Exchange the reactor. Samsung Electronics 12-18...
Page 81
12-2-18 The others 1. AC Line Zero Cross Signal OUT – Check the assembly condition of peripheral part of IC21, ZD21, ZD20 and D200 on the PCB. 2. Capacity miss match – Check again the indoor unit option code. 12-19 Samsung Electronics...
2) The fan motor of the indoor unit doesn’t run. • Fan Motor Connector(CN72) is faulty 3) The power voltage between terminal #3 and #5 • ASS’Y Main PCB is faulty of the connector(CN72) is 0V. • Connection is faulty Samsung Electronics 12-20...
Page 83
1) Is CN01 1, 3 over 250V? • Outdoor PCB Error 2) Is CN01 3, 5 within 1V~5V? • BLDC Motor Error 3) Is the voltage of CN01 6 changed? 4) Is the resistance of BLDC Motor 1, 3 opened after power off? 12-21 Samsung Electronics...
∞, 0Ω . . . Open or Short Stepping Motor Measure the resistance between the red wire and each terminal wire with a tester. Normal About 300Ω at the normal temperature (20˚C ~ 30˚C) Abnormal ∞, 0Ω . . . Open or Short Samsung Electronics 12-22...
: BLADE CONTROL SELECT(UP/DOWN) MELODY CONTROL PART SLEEP OPERATION DC5V VOLTAGE REGULATOR ANION SELECT SPEAKER AUTO CLEAN SELECT OPTION ENERGY SAVING SELECT DC12V SMPS POWER BLOCK SOUND ON/OFF SELECT DIGITAL ON/OFF DC5V DC12V AC230V AC INPUT DC25V 13-1 Samsung Electronics...
Page 86
Block Diagram INDOOR FAN CONTROL BUZZER CONTROL SMPS 485 COMMUNICATION SUB-PCB Samsung Electronics 13-2...
③ : Use the " ③ " digit for classification between indoor and outdoor. Indoor "N" & Outdoor "X". ④ : Use the “ ④ ” digit for KD models. "CKD" "1" & "SKD" "2". Except the RAC Export Models for China. 14-1 Samsung Electronics...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps.
Page 93
Also, the remote controller may not work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. 14-5 Samsung Electronics...
Page 94
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
Reassemble the air filter and the front panel. Hook Note : • If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly. 14-7 Samsung Electronics...
Front panel You can purchase deodorizing filter at the customer care center. The filter function is not affected even if deodorizing filter and anti-allergy filter are inverted. Hook Samsung Electronics 14-8...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 14-9 Samsung Electronics...
183kgf•cm with a torque wrench. 7) Check for gas leakage. - At this time, especially check for gas leakage from the 3 way valve’s stem nuts, and from the service port cap. Samsung Electronics...
• Make sure you do not bend the connection pipes in the middle and store together with the cables. • Move the indoor and outdoor units to a new location. • Remove the mounting plate for the indoor unit and move it to a new location. 14-11 Samsung Electronics...