-32DP PROFIBUS-DP Interface Block
3U
User's Manual
1.3.2

Applicable PLC

The FX
-32DP functions with an FX
3U
with an FX
/FX
3G
PLC's extension port.
The 32DP occupies 8 points on either input or output of the PLC extension bus. The FX
*2
FX5UC
PLC has a maximum of 256 controllable I/O points, whereas the maximum connectable special
function blocks for a single FX
has a maximum of 128 controllable I/O points, whereas the maximum connectable special function blocks for
a single FX
/FX
3G
FX
Series PLC
3G
*1
FX
Series PLC
3GC
FX
Series PLC
3U
*1
FX
Series PLC
3UC
*2
FX5U PLC
*2
FX5UC PLC
*1.
An FX
2NC
Series PLC.
However, the 32DP cannot be connected to the FX
*2.
An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect to the 32DP with the FX5U/FX5UC PLC.
1.4

FROM/TO Execution Time

The PROFIBUS cycle time and FROM/TO instruction operates asynchronously. If data is written to the 32DP
in the PROFIBUS cycle time, this data will move to the system area on the next PROFIBUS cycle time.
Reference
The FROM/TO Execution Time varies as follows, depending on the data amount to be transferred.
FROM/TO Execution Time details
1) FX
/FX
3U
3UC
The following table is also applicable to the other instructions accessing the 32DP BFMs from FX
FX
Series PLC.
3UC
FNC
Instruction
No.
FX
-32DP
3U
78
FROM
79
TO
2) FX
/FX
3G
3GC
FNC
Instruction
No.
FX
-32DP
3U
78
FROM
79
TO
Note
• The execution times above are approximate values for the FX
• The FROM/TO Execution Time varies depending on each special function block.
• It is not necessary to check all DP-Slaves' cyclic I/O data in a single PROFIBUS Cycle Time.
18
3G
*1
*1
/FX
/FX
/FX5U
3GC
3U
3UC
3UC *1
/FX
3U
*1
PLC is 8 units.
3GC
PLC Type
-CNV-IF or FX
-1PS-5V is necessary to connect to the 32DP with the FX
3UC
Series PLC
Execution time in ON status (µs)
16-bit instruction 32-bit instruction 16-bit instruction 32-bit instruction
15 + 250n
15 + 280n
Series PLC
Standard mode
Execution time in
ON status (µs)
16-bit
32-bit
instruc-
instruc-
tion
tion
20 +
25 +
225n
295n
20 +
25 +
290n
420n
*1
*1
/FX
/FX
/FX
/FX5U
3GC
3U
3UC
*2
*2
/FX5UC
PLC, connect the 32DP's extension cable to the
*2
*2
/FX5U
/FX5UC
PLC is 8 units. The FX
Version
Ver. 1.00 or later
Ver. 1.40 or later
Ver. 2.21 or later
Ver. 2.21 or later
Ver. 1.014 or later
Ver. 1.014 or later
-32MT-LT(-2).
3UC
Execution time in OFF status (µs)
15 + 320n
0.585
15 + 415n
0.585
Execution time in
Execution time in
OFF status (µs)
ON status (µs)
16-bit
32-bit
16-bit
instruc-
instruc-
instruc-
tion
tion
tion
25 +
0.61
0.61
225n
25 +
0.61
0.61
290n
1.4 FROM/TO Execution Time
*2
*2
/FX5UC
PLC. To set up the 32DP
3U
/FX
3G
1.105
1.105
n: The number of transferred data
Extension mode
Execution time in
OFF status (µs)
32-bit
16-bit
32-bit
instruc-
instruc-
instruc-
tion
tion
tion
25 +
0.8
0.8
295n
30 +
0.8
0.8
420n
n: The number of transferred data
-32DP.
3U
1 Introduction
3UC *1
*2
/FX
/FX5U
/
3GC *1
Series PLC
/FX
3GC
3UC
/
3U
Note
BFM#100 to #171
BFM#300 to #371
Note
BFM#100 to #171
BFM#300 to #371