Download Print this page

Parameter Setting - Parts Connect IM70 Service Manual

Household ice machine
Hide thumbs Also See for IM70:

Advertisement

status
1 ice making
short press mode button
cycle
2 SMG: OFF long press mode button
long press mode button,
release and then short
press mode button 1 time
long press mode button,
release and then short
press mode button 2 time
long press mode button,
release and then short
press mode button 3 time
long press mode button,
release and then short
press mode button 4 time
long press mode button,
release and then short
press mode button 5 time
long press mode button,
release and then short
press mode button 6 time
long press mode button,
release and then short
press mode button 7 time
long press mode button,
release and then short
press mode button 8 time

Parameter Setting

operation
lights and SMG shown
SMG: show current
number for 2 seconds
and then show 1xx
ice making light: on
SMG: show OFF for 10
seconds and then show
2xx
SMG: show OFF for 10
seconds and then show
2xx->3xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx->6xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx->9xx
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
Parameter 1 is used to modify the
thickness of ice cubes. xx will flash
during setting. Short press set button
can change the 1xx, from 100 to 119,
100 is thinnest. after setting, leave it
no-operation for 10 seconds and
system will automatically remember
the setting and go back to ice making
cycle. Default number is 111.
Parameter 2 used to set the ice
making time. Short press the set
button will change the 2xx from 200 to
209, see ice making time table.
Parameter 3 used to set the harvest
time. Short press the set button will
change the 3xx from 300 to 309, see
harvest time table.
Parameter 4 used to set the pre-chill
time. Short press the set button will
change the 4xx from 400 to 490, see
pre-chill time table.
Parameter 5 used to set the gap
between 2 self-clean procedures.
Short press set button can change the
5xx from 500 to 590, see self-clean
frequency table.
Parameter 6 used to set the maximum
lack-of-water alarm time. Short press
set button can change the 6xx from
600 to 609, see maximum lack-of-
water table.
Parameter 7 is used to set the
maximum water inlet time. Short press
set button can change the 7xx from
700 to 709, see maximum water inlet
table.
Parameter 8 is used to set the ice
making lapse time. Short press set
button can change the 8xx from 800 to
809, see ice making lapse table.
Parameter 9 is used to set the
maximum condenser temperature.
Short press set button can change the
9xx from 900 to 909, see maximum
condenser temperature table.
Parameter P is used to set the water
discharge frequency. Short press set
button can change the Pxx from P00 to
6
details

Advertisement

loading