Remote Controller (Optional Parts) - Mitsubishi FDCVA302HENR Manual

Split system, air to air heat pump type
Table of Contents

Advertisement

(2) Remote controller (Optional parts)

(a) Wired remote controller
Installation with wiring exposed
2
0.3mm
, 3cores (O.D.ø5.6)
LCD display
Precation in Extending the Remote control cord
The cord should be a shielded wire.
● For all types : 0.3mm
Note: (1) Use cables up to 0.5mm
cable at a vicinity point outside the remote control unit, if necessary.
Within 100-200m ............
Within 300m ............
Within 400m ............
Within 600m ............
● The shielded wire should be grounded at one side only.
48
120
Remote controller mounting dimensions
Remote controller
outline
For the passage
after wiring
12×7 Long hole
2
3 cores
2
(maximum) for those laid inside the remote control unit casing and connect to a different size
2
3 cores
0.5 mm
2
3 cores
0.75 mm
2
1.25 mm
3 cores
2
3 cores
2.0 mm
Installation with wiring recessed
120
46
23
44
11.5
Attachment hole
9×4.5 Long hole(4 pcs.)
Maximum total extension 600m.
Indoor unit
(This side is not grounded)
12
-
-
Wall
Wire
(Recessed)
Electrical box
(Locally Purchased)
19
Cut off with a knife or the
like thin walled parts intend-
ed for screw holes, and then
fix it with screws.
Earth wiring
Remote control cord
(Shielded wire)
Remote control switch
Unit : mm