Operation; Turning On The Fan; Selecting The Power Level; Delayed Shut Down - Miele DA 270 U Operating And Installtion Instructions

Table of Contents

Advertisement

Operation

Turning on the fan

^ Press the On/Off button.
The fan runs at power level "lI".
The indicator lights.

Selecting the power level

^ Use the _ buttons to select the
desired power level.
& = increases the fan speed
$ = decreases the fan speed
Level "1" to "3" (green indicators) are
usually sufficient for normal cooking.
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
10

Delayed Shut Down

If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
^ Press the Delayed Shut Down button
while the fan is still running:
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(left indicator lights)
To cancel the Delayed Shut Down
feature press the button again.

Turning off the fan

^ Press the On/Off button to turn off the
fan.
The indicator goes out.
Automatic Safety Shut Off
The fan will turn off automatically 10
hours after the last button was
activated. The lighting however will
remain on.
^ Press the On/Off button to turn the
fan back on again.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents