  • Page 1 ™ SuperFlo High Performance Pump Installation User's Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
  • Page 2 Trademarks and Disclaimers: SuperFlo is a trademark of Pentair Water Pool and Spa, Inc. The Pentair Pool Products logo is a registered trademark of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
  • Page 3: Table Of Contents

    Important Safety Precautions ... ii Section 1: Introduction ... 1 SuperFlo Pump Overview ... 1 General Features ... 2 Section 2: Electrical Requirements ... 3 Wiring Installation ... 3 Pump Strainer Basket ... 4 Section 3: Maintenance ... 5 Cleaning the Pump Strainer Basket ... 5 Winterizing ...
  • Page 4: Important Safety Precautions

    Important Notice: This guide provides installation and operation instructions for the SuperFlo Pump. Consult Pentair Water with any questions regarding this equipment. Attention Installer: This guide contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment after installation or left on or near the pump.
  • Page 5 IMPORTANT SAFETY PRECAUTIONS WARNING — Do not operate the pump until you have read and understand clearly all the operating instructions and warning messages for all equipment that is a part of the pool circulating system. The following instructions are intended as a guide for initially operating the pump in a general pool installation, however each installation may have unique conditions where the starting procedure could be different.
  • Page 6 SuperFlo Pump Installation and User’s Guide...
  • Page 7: Section 1: Introduction

    All pumps from Pentair Water Pool and Spa incorporate innovative hydraulic engineering that has been refined for over 40 years. SuperFlo reflects the latest and best Pentair technology, to move water more efficiently for lower operational costs. Compact, rugged, and easy to maintain, SuperFlo will deliver years of reliable service.
  • Page 8: General Features

    General Features • Extremely quiet operation • Unionized fittings (1.5" and 2") for simple replacement • Cam and Ramp™ lid for easy cleaning and maintenance • Heavy-duty, high service factor 56 square flange motor for long life • Integral volute and pot reduce hydraulic noise •...
  • Page 9: Section 2: Electrical Requirements

    This section describes how to wire the SuperFlo pump. Note: Before installing this product, read and follow all warning notices and instructions starting on page ii. Electrical Requirements and Wiring When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you MUST use a No.
  • Page 10: Pump Strainer Basket

    Wiring Installation, cont.’d. 6. Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground.
  • Page 11: Section 3: Maintenance

    This section describes how to maintain the SuperFlo pump. Cleaning the Pump Strainer Basket WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water.
  • Page 12: Winterizing

    Cleaning the Pump Strainer Basket, cont’d. 9. Reinstall the lid by placing the clamp and the lid on the pot; see a. Make sure the lid O-ring is properly placed. Seat the clamp and lid then turn clockwise until the handles are horizontal; see 10.
  • Page 13: Section 4: Servicing

    WARNING — Risk of electrical shock or electrocution. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
  • Page 14: Pump Reassembly/Seal Replacement

    Pump Disassembly, cont’d. h. To unscrew the impeller from the shaft, twist the impeller counter-clockwise. Remove the four bolts from the seal plate to the motor using a 3/8 inch wrench. Place the seal plate face down on a flat surface and tap out the ceramic seal. k.
  • Page 15: Section 5: Restart Instructions

    If the SuperFlo pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to reopen valves prior to operating. CAUTION — DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking.
  • Page 16: Section 6: Troubleshooting

    Section 6 Troubleshooting Use the following troubleshooting information to resolve possible problems with your SuperFlo pump. WARNING — RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Improperly installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property. 1.
  • Page 17: Section 7: Technical Data

    Illustrated Parts Item Part Description 075236 MOTOR SQ FL, 2 HPF, 2.5 A, 1 PHASE, 60 Hz, STD, 230V — (Almond) 075235 MOTOR SQ FL, 1.5 HPF, 2 A, 1 PHASE, 60 Hz, STD, 230/115V — (Almond) 075234 MOTOR SQ FL, 1 HPF, 1.5 A, 1 PHASE, 60 Hz, STD, 230/115V —...
  • Page 18: Pump Curve

    60.00 SF-N1-3/4A SF-N1-3/4A 50.00 40.00 30.00 20.00 SF-N2-1A SF-N2-1A 10.00 0.00 20.0 SAVE THESE INSTRUCTIONS SuperFlo Pump Installation and User’s Guide PENTAIR POOL PRODUCTS, INC. PUMP PERFORMANCE CURVE SUPERFLO ™ SERIES SF-N1-1.5A SF-N1-1.5A SF-N1-1A SF-N1-1A SF-N1-2A SF-N1-2A SF-N2-2A SF-N2-2A SF-N2-1.5A SF-N2-1.5A...
  • Page 19 NOTES...
  • Page 20 P/N 350096 Rev. B 4/28/06...