Network Set Up - Furuno FA-170 Installation Manual

Hide thumbs Also See for FA-170:
Table of Contents

Advertisement

3.6

Network Set Up

1. Access the [INITIAL SET] menu, following the procedure outlined in "How to ac-
cess the [INITIAL SET] menu" on page 3-1.
2. Select [NETWORK], then press the ENT/ACK key.
NETWORK
IP ADDRESS
172 . 031 . 024 . 004
SUBNET MASK
255 . 255 . 000 . 000
GATEWAY
000 . 000 . 000 . 000
OWN SFI
AI0001
[ RX SFI ]
LL/SOG/COG
GP0001
HDG
GP0002
ROT
GP0002
: CURSOR
: SELECT
ENT
Standard network settings screen.
3. [IP ADDRESS] is selected. Press the ENT/ACK key to show the IP address set-
tings pop up window.
4. Set the IP address, then press the ENT/ACK key.
5. Select and set [SUBNET MASK] and [GATEWAY] in a similar fashion. For NavNet
networks, go to step 6, for other network types, go to step 13.
6. Select [NAVNET PORT], then press the ENT/ACK key.
7. Input the NavNet port which this unit is connected to, then press the ENT/ACK
key.
8. Select [HOST NAME], then press the ENT/ACK key.
9. Input the name for this unit within the NavNet network, then press the ENT/ACK
key.
10. Select [AIS INFO], then press the ENT/ACK key.
11. Select [ON] to enable AIS data output to the NavNet network when this unit is
turned on. Select [OFF] to disable AIS data output when this unit is turned on.
12. Set [ZDA INFO] and [GPS INFO] in the same manner as [AIS INFO], then go to
step 18.
13. Select [OWN SFI] (System Function ID), then press the ENT/ACK key.
14. Set the [OWN SFI], then press the ENT/ACK key.
15. Select an option from the [RX SFI] options.
When part of a LAN network, the FA-170 may receive data for the same item from
several sources, resulting in unstable calculations. For stable calculations, set the
SFI for the sensor to be used as the fixed data source.
For example, if [LL/SOG/COG] is set as "AA111", the FA-170 only uses data from
the sensor with the ID "AA111" to calculate [LL/SOG/COG].
16. Input the network ID for the sensor.
17. Repeat step 15 to 16 as required.
18. Confirm the settings are correct, then select [<SAVE>] and press the ENT/ACK
key. A confirmation pop up is displayed.
Note: If no changes are made to the settings, [<SAVE>] is not selectable.
19. Select [NO] to change the settings further. Select [YES] to accept the new set-
tings, the unit now shuts down automatically to apply the new settings. After the
unit shuts down, press the power key to restart the unit.
NETWORK ( NAVNET )
IP ADDRESS
SUBNET MASK
GATEWAY
NAVNET PORT
HOST NAME
[ OUTPUT AT STARTUP ]
AIS INFO
ZDA INFO
GPS INFO
<SAVE>
: BACK
: CURSOR
MENU
NAVNET network settings screen.
3. SETTINGS AND ADJUSTMENTS
172 . 031 . 024 . 004
255 . 255 . 000 . 000
000 . 000 . 000 . 000
10000
AIS0
ON
OFF
OFF
: SELECT
ENT
MENU
<SAVE>
: BACK
3-9

Hide quick links:

Advertisement

Table of Contents
loading