Honeywell Searchline Excel Technical Handbook page 30

Infrared gas detectors
Hide thumbs Also See for Searchline Excel:
Table of Contents

Advertisement

MAN0530 Issue 10 - 11/09
2104M0506
3. INSTALLATION AND OPERATION
(4)
Fit an adjustment clamp to the unit's pivot block mounting stud so that it sits on the stud's
shoulder. The correct orientation for the pivot blocks and clamps is as follows:
(5)
Tighten the adjustment clamp's grubscrews until they just grip the unthreaded part of
the stud.
(6)
Fit the pivot block to the mounting bracket using a clamp nut and washer (M12 or M20).
The correct orientation for the pivot blocks and mounting brackets is as follows:
do not fully tighten the nut (refer to 3.73).
Mounting Plate Fixed to Twin Pipes/Poles
Mounting stud
Adjustment clamp
Clamp nut and
washer
2.5in. U-bolt - 4-off
(not supplied) using
A holes
Pivot block
Mounting
bracket
Mounting bracket
grubscrew