Parameter list for control unit MD-4-95-220-CE

.05.02
34
9
985
Switch on angle for thread trapper
986
Switch off angle for thread trapper
989
Thread trapper at beginning of seam
1 = yes, 0 = no
1
Speed max.
4
Speed for start backtackl
5
Speed for end backtack
40
Thread wiper
46
Rotating direction of the motor
47
Selected machine class
61
Cutting speed 1
81
Needle position 6 (start cutting signal 2)
84
Needle position 5 (end cutting signal 1)
85
Needle position 9 (start thread tension
release/start thread catcher)
87
Tension release after thread lever position at t.d.c.
179
Needle position 2 (take-up lever raised)
181
Needle position 1 - needle lowered (192 = off)
210
Switch on angle for thread trapper
211
Switch off angle for thread trapper
236
Machine version
0 = 1183; 1 = 1181
Further parameters see manual of the respective drive
B, C
0 -255
67
B, C
0 -255
206
B, C
0 - 2
0
50 - 9999
50 - 8000
50 - 8000
ON - OFF
CW - CCW
0 - 101
50 - 500
0 - 360°
0 - 360°
0 - 360°
0 - 1500ms
0 - 359°
0 - 255
0 - 359°
0 - 359°
0 - 20
67
206
0
1500
1500
ON
CW
62
220
40°
90°
120°
20ms
83°
250
20°
90°
0