  • Page 2 PREAMBLE – QUALITY PHILOSOPHY You have chosen to purchase a SPARTHERM stove – thank you for the trust you have placed in us. In a world characterised by an abundance of choice and mass production, our company name is associated with the principles: “High technical quality combined with contemporary design and service for...
  • Page 3: Table Of Contents

    CONTENT 1. Information 7. Mechanical components 1.1 General Remarks 7.1 Rear wall 1.2 Technical data Mellino 7.2 Removing the combustion chamber door 1.3 Scope of Delivery 7.3 Combustion chamber lining 1.4 Accessories 7.4 Screw feeder 1.5 Dimensions 7.5 Removing the side cladding 2.
  • Page 4: Information

    This instruction describes the assembly and the possible service work electrical power consumption in standby approx. 2 W required for the pellet stove Mellino. In the first instance, it is intended for electrical power consumption when starting the stove fitter, installation engineer or service technician.
  • Page 5: Scope Of Delivery

    1.3 SCOPE OF DELIVERY 1.5 DIMENSIONS The Mellino is supplied ready mounted on a wooden pallet. The following parts belong to the scope of supply and must be enclosed with the device: • Scrubber cleaner printed glass ceramics, • Handle for the burner pot (lifting...
  • Page 6: Assembling Instructions

    2. ASSEMBLING INSTRUCTIONS 2.2 SAFET Y DISTANCES The assembly of the pellet stove must only be carried out by an authorised A minimum distance of 150 mm must be maintained to combustible objects specialist company. The device must be positioned fixed and safe on a non- (furniture, decoration, curtains, etc.) positioned on the sides.
  • Page 7: Chimney Connection

    2.3 CHIMNEY CONNECTION Conventional wall connection The pellet stove must be connected to a chimney that has been approved for With a chimney orifice positioned a little higher, the wall distance increases solid fuels. Multiple allocation not permitted in the process! The dimension- according to the connecting pieces used.
  • Page 8: Combustion Air

    Via an external combustion air connection If the pellet stove Mellino should be supplied with a separate combustion air line, this must be connected to the flue gas connection (Ø 100 mm) at the rear (see „1.5 Dimensions“).
  • Page 9: Electrical Connection

    The pellet stove is supplied with an approx. 2 m connecting lead with earth- ing contact plug. The connection to the power network must only be carried The control system in the Mellino is characterised by several special out on a earthing contact plug installed correctly and earthed according to features.
  • Page 10: Infinitely Variable Capacity Control

    5.1 THE DISPLAY The first 3 symbols, at top left, are warnings. Adjacent to these 3 symbols is the receiver for the remote control unit and a display that shows whether a timer program is activated. With the menu buttons you can move to the other 6 displays and then set them.
  • Page 11: The Remote Control

    10 Room temperature and target temperature in °C To control the stove using the remote control, you need a free view of the stove display. The receiver is located in the top section of the display. The 11 Pellet type selection (1, 2 or 3) commands of the remote control are shown in the display.
  • Page 12 Level 3: Display representation when idling Depending on the setting, the display shows different information approx. 2 minutes after pressing the key for the last time. Service symbol OFF: the display remains in the indicator last selected 1: the display shows the time and the current room temperature alternately Level 1: Keypad lock every 5 - 6 seconds Here the display can be blocked against unauthorised operation as well...
  • Page 13 This value cannot be adjusted. • Press the ESC key at the top left 2 times to return to the main menu • Go to level 5 in the service menu using the + / - setting keys, a [ 5 ] •...
  • Page 14 Proceed as follows for editing the parameters: • Use the menu keys to go to the desired parameter. • Go to level 8 in the service menu using the + / - setting keys, • Press Enter and the current setting value of the parameter appears [ P A r ] appears •...
  • Page 15 PreS shows the current pressure difference that is kept constant by the Sc00: Number of ignition processes control system, see 4.1. Sc01: Number of overtemperature deactivations Sc02: Number of faulty ignitions Level 11: Digital outputs Sc03: Operating hours on the main voltage Sc04: Once the service menu has been activated (see level 7), in level 11 you can Operating hours in heating mode...
  • Page 16: Mechanical Components

    If it should be necessary to remove parts of the cladding, the following notes must be observed: • Opening the cladding or the replacement of parts on the Mellino must only be carried out by an instructed specialist. • Disconnect the power plug from the socket before opening the cladding each time! •...
  • Page 17: Removing The Combustion Chamber Door

    7.2 REMOVING THE COMBUSTION CHAMBER DOOR 7.3 COMBUSTION CHAMBER LINING • Open the combustion chamber door. The firebox lining comprises Vermiculite and has the following structure: • Remove the retaining spring on the top door pin (image). • Lift the door upwards and out of the bottom guide. •...
  • Page 18: Screw Feeder

    7.4 SCREW FEEDER 7.5 REMOVING THE SIDE CLADDING • Removing the gear motor (see „8.3. Screw feeder drive“). • Remove the top plate. • Remove the adjusting ring. • Remove the protective grid by undoing the two hexagon socket screws •...
  • Page 19 Pic. 2 Pic. 4 Pic. 5 Pic. 3 GB 19...
  • Page 20: Electrical Components

    • Take care that the pellet supply tank is close so that no tools can fall into it. 8.1 MAINS FUSE The Mellino is safeguarded using a mains fuse F1 = T2A (10.3 x 38 mm). A replacement fuse is also in the fuse holder. • Remove the power plug from the socket.
  • Page 21: Fuse Of The Convection Air Blower

    8.3 SCREW FEEDER DRIVE The screw feeder is driven via a geared motor.. • Remove the power plug from the socket. • Remove the back wall. • Disconnect the 4-pin plug connection from the geared motor. • Undo the grub screw using an Allen key (image). •...
  • Page 22: Igniting Element

    8.4 IGNITING ELEMENT 8.5 FLUE GAS FAN The igniting element comprises igniter cartridge and igniter tube. The flue gas fan comprises a spiral housing with motor and is screwed to • Remove the power plug from the socket. the base plate of the ash box with 3 hexagon socket screws. The flue gas •...
  • Page 23: Convection Air Blower

    8.6 CONVECTION AIR BLOWER 8.7 FLUE GAS TEMPERATURE SENSOR The convection air blower (optional component) is screwed on to the com- The flue gas temperature sensor is secured to the outlet of the flue gas fan bustion air box. using a squeeze-type threaded joint. •...
  • Page 24: Room Temperature Sensor

    Details on the warranty services, exemption of warranty as well as liability Test fire Fan 1 speed 18 Druckdifferenz Abgasgebläse bei test fire conditions can be obtained in the „Operating instructions Mellino“. Heat Up Fan 1 speed 14 Druckdifferenz Abgasgebläse bei Heat Up Fuel ignition Fan 1 speed 26 Druckdifferenz Abgasgebläse bei fuel ignition...
  • Page 25 255 205 Drehzahl Konv.lüfter auf Stellung Hi Quickheat Fan 2 speed Pellets quality Anpassung Pelletssorte, auf 1 belassen Stop Fire Fan 3 speed Drehzahl Lüfter 3 w ährend Stop fire Phase Wood quality auf Stellung 1 belassen, nur bei Holzbrand Test fire Fan 3 speed Drehzahl Lüfter 3 w ährend Test fire Phase Time to service...
  • Page 26: Error Code List

    10.2 ERROR CODE LIST Error code Meaning / remedy Here is a list of the error codes (see chapter 6, level 13). If an error is reported, determine and eliminate the cause. The errors can be reset by E110 NTC1 defective (room temperature sensor) pressing the On / Off key.
  • Page 27: Circuit Diagram Terminal Strip X1

    10.4 CIRCUIT DIAGRAM TERMINAL STRIP X1 10.5 CIRCUIT DIAGRAM TERMINAL STRIP X2: CONTROLLER NTC room temperature sensor Flue gas temperature sensor (K type) Before the baffle plate (on the aluminium tube) Convection air fan Flue gas fan Behind the baffle plate to control system: power supply 230V Mains feed to X1 : 1 and X1 : 3 to control unit: connection of flue gas fan...