Planet VC24024 Quick Installaion Manual

Vdsl2 ip dslam

Advertisement

Quick Links

VDSL2 IP DSLAM
VC-2402 / VC-2402-48
Quick Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Planet VC24024

  • Page 1 VDSL2 IP DSLAM VC-2402 / VC-2402-48 Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents Mandatory Regulations ..................3 Package Contents .................... 5 1. Installation of the VC-2402 ................6 1.1 Pre-Installation ..................6 1.1.1 Tools and Test Equipment Requirements ........6 1.1.2 Safety Requirement ..............6 1.1.3 Electrostatic Discharge Protection ..........6 1.2 Hardware Installation ................
  • Page 3 2.1.3 Dispatching Maintenance Personnel ..........25 2.1.4 Electrostatic Discharge Protection ..........25 2.1.5 Routine Maintenance ..............25 2.2 Powering the VC-2402 Up or Down ............26 2.3 Controls and LED Indication ..............27 2.4 Cleaning Units ..................29 3. Troubleshooting the VC-2402 ..............30 3.1 Introduction to Troubleshooting ............30 3.2 Resolving Problems Indicated Through LEDs .........30 3.3 Resolving Problems Indicated Through Alarms........30 3.4 Procedures for Troubleshooting the VC-2402 .........30...
  • Page 4: Mandatory Regulations

    Mandatory Regulations The following sections describe the mandatory regulations that govern the installation and operation of the VC-2402. List of Terms Table 1 lists the terms used in this chapter. List of Terms Term Expansion Conformité Européenne European Standards Federal Communications Commission Telecommunication Standardization Sector of the International ITU-T Telecommunications Union...
  • Page 5 Regulations compliance Safety Approval The system complies with the following safety norms: – Product Safety Requirements identified in EN60950:2000 – Over Voltage Protection Requirements of ITU-T K.20 EMI/EMC The system meets the requirements of Telecommunications Network Equipment: EN300-386. Electromagnetic Compliance The system complies with the standard FCC Part 15 Class A and EN55022. RoHS The system complies with the RoHS.
  • Page 6: Package Contents

    Package Contents VC-2402 / VC-2402-48 • VC-2402 / VC-2402-48 Unit x 1 • AC / DC Power Cord x 1 • CD (Containing User’s Manual, QIG) x 1 • Quick Installation Guide x 1 • 2-Meter Telco-50 Cable x 2 •...
  • Page 7: Installation Of The Vc-2402

    1. Installation of the VC-2402 1.1 Pre-Installation This section provides the information users have to ware before installing the VC- 2402. The information includes required installation tools, safety requirements, and electrostatic discharge protection. 1.1.1 Tools and Test Equipment Requirements To install and maintain the VC-2402, you should have the tools and test equipment listed in the Table 1-1.
  • Page 8: Hardware Installation

    1.2 Hardware Installation The hardware installation for the VC-2402 is simple and without complex hardware setting. However, it should be installed following out the standard installation procedures. During installation, basic safety precaution should always be taken, especially, be sure to wear an antistatic wrist strap to prevent static electricity from damaging the system and injury to the operator.
  • Page 9: Mounting The Vc-2402

    Step 4: Connect Console cable to COM port of a computer. Then run the terminal program with the setting shown below: Console Setting Users can also access the DSLAM via Ethernet. By default the out-band IP address of the DSLAM is obtained via DHCP. Users can also set the IP address manually by using the CLI commands or Web Configuration Tool (refer to section 1.3). It’s possible to access the DSLAM with telnet on port 23.
  • Page 10 After the site requirements have been verified, the chassis may be installed at the specified location. When mounting the chassis, practice good safety habits. Use two or more people to secure the chassis. Relay rack mounting normally requires at least two people. Step Action Locate the chassis and obtain the appropriate chassis mounting...
  • Page 11: Power And Ground Connections

    1.2.4 Power and Ground Connections Power connection of VC-2402 AC Power Connection If your VC-2402 uses AC power, connect the AC power cord to the AC supply socket on the front panel of the DSLAM, and plug the cord into the external power source.
  • Page 12: Connecting The Vdsl/Adslx And Pots Interfaces

    Ground Connections This section provides the grounding rule for the VC-2402. All remote system sites must be properly grounded for optimum system performance. In Central Office: There should be a CO GND that is adequately grounded. If the measured resistance from the grounding screw (on the front panel of the DSLAM) to CO GND is less than 5 Ohm, then it can be assumed that the system is well grounded.
  • Page 13 For Line port 1~24: PIN No P13 P11 P11 Port No. P12 P12 P10 P10 PIN No PIN No P23 P23 P21 P21 P19 P19 P17 P17 P15 P15 P13 Port No. P24 P24 P22 P22 P20 P20 P18 P18 P16 P16 P14 P14 PIN No Pin Assignment of LINE Interface For POTS port 1~24:...
  • Page 14: Connecting The Gbe1/Gbe2 Trunk Interface

    1.2.6 Connecting the GBE1/GBE2 trunk interface The system provides two types of trunk interfaces (two ports for each type): electrical (RJ-45) and optical (mini-GBIC) interfaces. When both electrical and optical ports are connected, system will automatically select the interface according to the priority setting (Fiber first or Copper first).
  • Page 15: Ethernet Port (Mgmt)

    Never look directly at the transmitting ports of optical interface that might be emitting laser, in order to prevent damage to the eye from the laser radiation. Warning 1.2.7 Ethernet Port (MGMT) The VC-2402 provides one RJ45 Jack (MGMT) on the front panel for Ethernet interface connection. The detailed pin assignment is shown in the following figure and table.
  • Page 16: Console Port (Cid)

    1.2.8 Console Port (CID) The Console interface (CID) on the front panel is the main control interface of the VC-2402. The RJ45 connector pin assignment is illustrated below: 1 2 3 4 5 6 7 8 Other pins unused Console Port RJ-45 pin assignment To connect the host PC to the console port, a RJ45 (male) connector-to-RS232 DB9 (female) connector cable is required.
  • Page 17: Housekeeping And Alarm Contact Output Interface

    1.2.9 Housekeeping and Alarm Contact Output Interface The VC-2402 has an RJ-50 port (HK) on the front panel to provide four housekeeping inputs and one alarm contact output. Generally, housekeeping contacts can connect to environment-sensor- controlled switch to indicate the operation environment condition.
  • Page 18: Provisioning A Management Ip Port

    Operation diagram of Housekeeping Inputs and Alarm Contact Output The maximum current and voltage for ALMOUT / ALMCOM is restricted to 0.5 A 30 VDC or 0.15 A 125 VAC (resistive load). Note 1.3 Provisioning a Management IP port This section describes how to use CLI commands or Web GUI to provision an IP port for the VC-2402.
  • Page 19 In the PC terminal screen, type in the login user name and password to login the system. Type the following CLI command to check current IP setting of all the management ports. enable /*Go to enable command mode*/ show management /*Display all system management port IP setting*/ WDS login: admin Password:...
  • Page 20 management mgmt <ipv4 address> [<netmask>] [<default_gateway>] /*Set out-band management port IP setting*/ runningcfg save [<inbandBackupName>] [<generalBackupName>] /*Save new setting to memory*/ After setting the in-band/out-band IP of the VC-2402, remember to connect its Ethernet port MGMT to the Ethernet LAN. Then in the previous PC terminal screen, type the following command to verify if the Ethernet connection between the management station and the DSLAM is working.
  • Page 21 d. Click on Modify button to apply the modification. Please remember to save new settings to flash memory: On the menu tree, click on Maintenance ---> Database. The Database Configuration page is displayed. Click on the Database Control Action drop-down list and select (A) Save runtime config. and set to new active DB then click on Submit button (you can specify the DB filename to save or let system determine). This will save inband configuration and runtime configuration as the active restoration database for next power-on restoration.
  • Page 22: Configuration Import/Export

    1.4 Configuration Import/Export The configuration database of VC-2402 contains two kinds of database - inband database and general database. Inband database contains configuration for the inband channel and is shared by two boot images (no matter which boot point you choose, the inband configuration keeps the same). General database contains other configuration.
  • Page 23 (F) Clear active DB excluding inband / (G) Clear active DB excluding inband and restart: enable configure runningcfg clear general [noreboot] /*You must add the word “noreboot” for action (F) so that the system will not reboot auto- matically once the DB is cleared*/ (H) Export in CLI command format: enable configure...
  • Page 24: Firmware Update

    1.5 Firmware Update To update firmware or bootloader, the VC-2402 must get the firmware files from an FTP Server in which the firmware image and checksum file have been put. It is suggested to set the ‘connection timeout’ of the FTP server no less than 3 minutes (i.e. 180 seconds), in order to prevent firmware update failure due to FTP timeout for some FTP servers. Note Following paragraph describes the procedures and commands to use when users want to upgrade the firmware /bootloader by using CLI.
  • Page 25 //go to enable mode localhost:>enable //go to configuration mode localhost:%configure localhost:(conf)#firmware write <FTP server ip address> <username> <password> <filename> {image|bootloader} [noreboot] //get files from FTP server and write to FLASH. // The word “noreboot” in this command is optional. If you add it in the command, you must reboot the system manually for the changes to take effect; otherwise the system will reboot automatically once the firmware/bootloader is updated. Description Perform software image or bootloader remote download.
  • Page 26: Operating And Maintaining The Vc-2402

    2. Operating and Maintaining the VC-2402 2.1 Maintenance requirement 2.1.1 Tools and Equipment Requirements Lists required tools and test equipment for the VC-2402 system maintenance. Required Installation Tools and Materials Item Required Purpose Anti-static wrist strap Protect the system from electrostatic discharge damage Hand tool Screwdrivers for equipment removal and replacement Wire cutter/stripper...
  • Page 27: Powering The Vc-2402 Up Or Down

    Also keep each VC-2402 system site free of dust and other pollutant that could affect system performance. In addition, be sure to maintain the environment conditions at the central office and at each remote system site. The ideal operating temperature is about 20°C. The following is the acceptable operating condition range: -40°C to 65°C and 5% to 95% humidity at 35°C (using DC power, Model: VC- ó...
  • Page 28: Controls And Led Indication

    2.3 Controls and LED Indication The VC-2402 has simple controls and indicators on its front panel. The indicators show the current operating states of various system elements and serve as maintenance aids for local technicians at each site. The remaining controls on the cards are also provided for local system testing and maintenance.
  • Page 29 Green - On Valid Ethernet connection established MGMT-Link/Act Disconnection (LED A on RJ-45) Green - Blink Transmitting or receiving data Amber At power on phase Self-test fail Green Normal Operation Green - Blink Remote download in operation At power on phase Major alarm set Red –...
  • Page 30: Cleaning Units

    2.4 Cleaning Units This section provides procedures on how to: clean the air filter every three months ó Air Filter Panel Procedure Clean the Air Filter You must loosen the connection of the Air Filter Panel to the DSLAM and pull out the Air Filter before cleaning the air filter. Note 1 Put on the antistatic wrist strap and connect it to a grounding point.
  • Page 31: Troubleshooting The Vc-2402

    3. Troubleshooting the VC-2402 3.1 Introduction to Troubleshooting This chapter describes instructions for the VC-2402 system problems. These procedures may require the presence of technicians at remote VC-2402 system sites and plus an operator at PC to monitor system alarms by console or EMS during maintenance.
  • Page 32 Table 3-2 List of Troubleshooting Procedures Procedure Type of problem Number VC-2402 power up problems Fiber optics problems VDSL/ADSLx service problems (POTS service is ok) POTS service problems (VDSL/ADSLx service is ok) Subscriber service problems (no POTS and VDSL/ADSLx service) Procedure 3-1 Troubleshoot VC-2402 Power Up Problems Problem indication: •...
  • Page 33 Procedure 3-3 Troubleshoot VDSL/ADSLx Service Problems Problem indication: No VDSL/ADSLx service to the affected subscribers (POTS service is ok). 1 If all subscribers connected to the DSLAM are affected, and the SYS LED on the front panel is not lit, check the power switch on the front panel: •...
  • Page 35 2011-AC0200-000...