Problem
Possible Cause
Corrective Action
Low heat, LP gas
Sudden drop in gas
flow or low flame
Cooking
light will not
turn on.
The propane
regulator
assembly
incorporates
an excess flow device
designed
to supply the grill with
sufficient
gas flow.
Rapid changes
in
pressure can trigger
the excess flow
device,
providing
a low flame
and
low temperature.
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor
lock at coupling
nut/LP
cylinder
connection.
1. No power supply.
2. Defective
halogen
bulb.
3. Internal wiring
issue.
Please follow
these instructions:
1. Make sure
all burners are "OFF".
2. Open the tank
valve and wait 5 minutes. 3. Light the burner
one at a time following
the lighting
instructions
listed on the door liner
1. Check for gas in LP cylinder.
2. Turn off knobs, wait 30 seconds and light
grill. If flames are still low, turn off knobs
and LP cylinder
valve. Disconnect
regulator.
Reconnect
regulator
and leak test. Turn on LP
cylinder
valve, wait 30 seconds and then
light grill.
3. Turn off knobs and LP cylinder
valve.
Disconnect
coupling
nut from cylinder.
Reconnect
and retry.
1. Check power supply and make sure
transformer
is properly
plugged
in.
2. Replace the bulb.
3. Check the wiring
connections
under the
fire box. All wire connections
must be tight.
If
any wires are damaged
they should be
replaced.
33

Advertisement

loading