13
Feed dog motion of bottom feed dog
.05.07
Requirement
With the needle bar at a position 0.6 past b.d.c. on the PFAFF 1181 or in position 0.6 past
t.d.c. on the PFAFF 1183 the feed dog must not make any feeding motion when reverse-
feed lever 3 is operated at the longest stitch length setting.
Fig. 13 - 8
Set the longest stitch and the needle bar at the corresponding position.
●
Adjust eccentric 1 (loosen screws 2 a little) according to Requirement, but make sure it
●
is not moved sideways.
2
1
Adjustment
3
13