Power Supply Trouble Shooting Chart - Acer AF715 Series Service Manual

Hide thumbs Also See for AF715 Series:
Table of Contents

Advertisement

BEFORE CHECK SW.REG. PLEASE REFER TO THE POWER SUPPLY BLOCK DIAGRAM
POWER SUPPLY OUTPUT: (A) CONSTANT OUTPUT : 6.5V, 16V, 80V, 180 V, -10V
BEAD SET
CHECK AC LINE
VOLT 120V OR 220V
NG
OK
CHECK LINE RECTIFIED
& SMOOTHED VOLT
NG
OK
CHECK START C.K.T
CHECK START C.K.T
ZD902,Q904,D909,R908
D909, Q904, R922, R925
NG
OK
CHECK T901 O/P
NG
OK
CHECK IC901
NG
OK
CHECK Q901

6-10 POWER SUPPLY TROUBLE SHOOTING CHART

CHECK F901, SW901
CHECK BRIDGE
RECTIFIED CIRCUIT
CHECK POWER SAVING
C.K.T(OFF-MODE)
CHECK 180V,80V,
CHECK 80V, 55V, 14.5V
16V, 6.5V
6.3V CIRCUIT
CIRCUIT
IC901 FAILURE
ABNORMAL VARIABLE OUTPUT
MAKE SURE THAT
THE VARIABLE
OUTPUT IS NOT SHORTED
YES
CHECK THE C934
VOLTAGE 55V
OK
CHECK Q911
OK
CHECK Q912, Q914, Q915
NG
CHECK Q901
21
NO
CHECK IC401
PIN 4, 5, 6, B+ DRIVER
NG
CHECK D919
NG
Q911 FAILURE
OK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents