3. INSTALLATION AND PREPARATIONS FOR USE

3.2 Electric connection and safety

• WARNING: Before obtaining access to terminals, all supply circuits must be disconnected.
• IMPORTANT:
The wires in mains lead coloured in accordance with the following code:
GREEN and YELLOW..............EARTH
BLUE......................................NEUTRAL
BROWN or RED......................LIVE
• This appliance must be installed by unauthorized person in accordance with the latest edition of
the IEE regulations and in compliance with the manufacturer instructions.
• Before proceeding with the electrical connection, verify that the current carrying capacity of the
system and the socket is adequate for maximum power rating of the oven.
• Electrical installation of the residence and the electrical current plug in use must be earthed and
conform to safety regulations. If there is no appropriate earthed electric outlet with regulations
in the place where the appliance will be installed, immediately contact to our authorized service.
The earthed electric outlet must be close to the appliance. All pole disconnection circuit breaker
with a contact opening of at least 3 mm must be installed inside the supply circuit.
• Fused switch must be accessible once the product has been installed.
• IMPORTANT: The following diameters of the supply cable must be used at least in case of one
phase connection;
Current on
rating label
0-3 A
3-10 A
10-16 A
16-40 A
40-...A
• Do not use adaptors, multiple sockets and/or extension cord.
• The supply cord should be kept away from hot parts of appliance. Otherwise the cord may be
damaged, causing short circuit.
• In case the cord is damaged, contact Authorized Service to have it changed.
Diameter of
supply cable
at 220 V
3x0.75
0-599W
3x1
600-2099W
3x1.5
2100-3349W
3x2.5
3350-8199W
3x4
8200-.....W
10
Rated power on rating label
at 230 V
0-699W
700-2299W
2300-3649W
3650-8999W
9000-.....W
at 240 V
0-799W
800-2499W
2500-3949W
3950-9799W
9800-.....W