Siemens INOX PRO SIMATIC IPC277D Service Manual page 15

Industrial pc, industrial monitor
Hide thumbs Also See for INOX PRO SIMATIC IPC277D:
Table of Contents

Advertisement

Procedure
1. Remove the seal from the front.
2. Insert the spare seal in the device front as shown in the figure. Make sure that the
positioning tabs of the seal are fully inserted into the corresponding bore holes of the
front.
3. Check the seal for correct seat, especially that the bore holes of the seal enclose the
collar of the press-fit components.
Connecting the cables and closing the device
Close the device when you are done with the maintenance work:
1. Connect the cables between the front and the rear panel. Perform steps 4. to 7. in the
section "Opening the device and loosening cables (Page 12)" in reverse order.
2. Close the device as shown in the figure below.
Make sure that you do not pinch the cables between the front and the rear panel.
3. Then fasten the rear panel according to the section "Fastening the rear panel (Page 21)".
SIMATIC IPC277D 19" INOX PRO, SIMATIC IFP1900 INOX PRO
Service Manual, 03/2015, A5E35751762-AA
Extended maintenance work
4.3 Replacing the seal of the rear panel
15