8.4.4

Opt. No. (Option numbers)

Select this sub menu to set all options at once (expressed in
two long strings of numbers).
An option number (or "option byte") represents a number of
different options. When you change these numbers directly,
you can set all options very quickly. All options are controlled
via eight option numbers.
When the NVM is replaced, all options will require resetting. To
be certain that the factory settings are reproduced exactly, you
must set both option number lines. You can find the correct
option numbers on a sticker inside the TV set and in Table

"Option code overview".

Example: The options sticker gives the following option
numbers:
04368 00005 01066 08707
00000 00032 00512 00000
The first line (group 1) indicates hardware options 1 to 4, the
second line (group 2) indicates software options 5 to 8.
Every 5-digit number represents 16 bits (so the maximum value
will be 65536 if all options are set).
When all the correct options are set, the sum of the decimal
values of each Option Byte (OB) will give the option number.
See tables "Option code overview" for the options.
Diversity
Not all sets with the same Commercial Type Number (CTN)
necessarily have the same option code!
Use of Alternative BOM
An alternative BOM number usually indicates the use of an
alternative display. This results in another display code thus in
another Option code. Refer to chapter 2 "Safety Instructions,
Warnings, and Notes".
8.4.5
Option Code Overview
Table 8-5 Option code overview
CTN_alt BOM#
Options Group 1
41609 03076 00343 13889 09079 00000 00000 00000
32PFL9432/98
42PFL9532/9x_1 41641 03590 00343 13889 09021 00000 00000 00000
42PFL9532/9x_2 41641 03590 00343 13889 09057 00000 00000 00000
42PFL9900/98_1 33497 09736 00343 13889 09057 00000 00000 00000
42PFL9900/98_2 33497 09736 00343 13889 09021 00000 00000 00000
47PFL9532/9x_1 41641 03590 00343 13889 09023 00000 00000 00000
47PFL9532/9x_2 41641 03590 00343 13889 09061 00000 00000 00000
Important: after having edited the option numbers as
described above, you must press OK on the remote control
before the cursor is moved to the left!
8.5

Reset of Repaired SSB

A very important issue towards a repaired SSB from a service
repair shop, implies the reset of the NVM on the SSB.
A repaired SSB in service should get the service Set type
"00PF0000000000" and Production code "00000000000000".
Also the virgin bit is to be set. To set all this, you can use the
ComPair tool.
Displ.
Options Group 2
(code)
119
061
097
097
061
063
101
Alignments
Q528.1A LA
8.
EN 163