Panasonic NE-3280 Service Manual page 26

Hide thumbs Also See for NE-3280:
Table of Contents

Advertisement

NE-3280 / NE-3240 / NE-2180 / NE-2140
DISPLAY
F34
Short temperature
sensor (exhaust)
F44
F01
Exhaust temperature
(With continuous
exceeds 120°C
beep sounds)
F03
Input voltage exceed +
12.5%
F04
Input voltage is less
than — 12.5%
F05
Memory failure
No display
1.25/3A fuse blown
No display
1.25/3A fuse is OK
F81
No voltage supply to
high voltage trans.
(lower/left)
F82
No voltage supply to
high voltage trans.
(lower/right)
F83
No voltage supply to
high voltage trans.
(upper/left)
F84
No voltage supply to
high voltage trans.
(upper/right)
F86
Shorted contacts of RY-
3
F87
Shorted contacts of RY-
5
F88
Shorted contacts of RY-
7
F89
Shorted contacts of RY-
9
[TROUBLE]Oven does not operate at all or oven does not start cooking. NE-2180, NE-2140
DISPLAY
F33
Open temperature
sensor (exhaust)
F34
Short temperature
sensor (exhaust)
F44
F01
Exhaust temperature
(With continuous
exceeds 120°C
beep sounds)
F03
Input voltage exceed +
12.5%
F04
Input voltage is less
than — 12.5%
F05
Memory failure
No display
1.25/3A fuse blown
CONDITIONS
1. Temperature sensor failure
2. Digital programmer circuit failure
1. Shorted power select switch
2. Shorted membrane switch
1. Burning food in the oven due to over cook
1. Increase in power source voltage
1. Decrease in power source voltage
1. Digital programmer circuit failure
1. Switch failure (short switch)
2. Low-Voltage transformer failure
1. Thermal cutout failure
2. Low voltage transformer failure
3. Digital programmer circuit failure
1. Relay failure RY-3 (A)
2. Loose connector CN256, CN257
3. Digital programmer circuit failure
1. Relay failure RY-5 (B)
2. Loose connector CN258, CN259
3. Digital programmer circuit failure
1. Relay failure RY-7 (C)
Loose connector CN260, CN261
2. Digital programmer circuit failure
1. Relay failure RY-9 (C)
Loose connector CN262, CN263
2. Digital programmer circuit failure
1. Replay failure RY-3 (A)
2. Digital programmer circuit failure
1. Replay failure RY-5 (B)
2. Digital programmer circuit failure
1. Replay failure RY-7 (C)
2. Digital programmer circuit failure
1. Replay failure RY-9 (D)
2. Digital programmer circuit failure
CONDITIONS
1. Temperature sensor failure
2. Digital programmer circuit failure
3. Loose connector CN5
1. Temperature sensor failure
2. Digital programmer circuit failure
1. Shorted power select switch
2. Shorted membrane switch
1. Burning food in the oven due to over cook
1. Increase in power source voltage
1. Decrease in power source voltage
1. Digital programmer circuit failure
1. Switch failure (short switch)
2. Low-Voltage transformer failure
POSSIBLE CAUSE
POSSIBLE CAUSE
26
TIMING OF FAILURE INDICATION
It is appeared when failure occurred.
It is appeared 2 minutes after failure
occurred.
It is appeared when exhaust temperature
exceeds above 120°C.
It is appeared when the unit is plugged in.
Note that it returns normal operation mode
by tapping the RESET pad ( ).
It is appeared when the unit is plugged in.
Note that it returns normal operation mode
by tapping the RESET pad ( ).
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared when failure occurred.
TIMING OF FAILURE INDICATION
It is appeared when failure occurred.
It is appeared when failure occurred.
It is appeared 2 minutes after failure
occurred.
It is appeared when exhaust temperature
exceeds above 120°C.
It is appeared when the unit is plugged in.
Note that it returns normal operation mode
by tapping the RESET pad ( ).
It is appeared when the unit is plugged in.
Note that it returns normal operation mode
by tapping the RESET pad ( ).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne-3240Ne-2180Ne-2140

Table of Contents