Schematic Diagrams - Sharp 27K-S100 Service Manual

Table of Contents

Advertisement

DESCRIPTION OF SCHEMATIC DIAGRAM
NOTES:
H
1. The unit of resistance "ohm" is omitted.
(K=k Ω =1000 Ω , M=M Ω )
2. All resistors are 1/8 watt, unless otherwise noted.
3. All capacitors are µ F, unless otherwise noted.
(P=pF=µµF)
4. (G) indicates ±2% tolerance may be used.
5.
indicates line isolated ground.
G
6.
indicates hot ground.
VOLTAGE MEASUREMENT CONDITIONS:
1. All DC voltages are measured with VTVM connected
between points indicated and chassis ground, line
voltage set at 120V AC and all controls set for normal
picture unless otherwise indicated.
F
2. All voltages measured with 1000µ V B & W or Color
signal.
E
WAVE FORMS
D
C
B
A
1
2
3
27K-S100/180/300/400
CK27S10/18/30/40
WAVEFORM MEASUREMENT CONDITIONS:
1. Photographs taken on a standard gated color bar
signal, the tint setting adjusted for proper color. The
wave shapes at the red, green and blue cathodes of
the picture tube depend on the tint, color level and
picture control.
2.
indicates waveform check points (See chart,
waveforms are measured from point indicated to
chassis ground.)
å
AND SHADED (
) COMPONENTS
= SAFETY RELATED PARTS.
' MARK= X-RAY RELATED PARTS.
å
DRGANNES MARQUES
ET HACHRES (
PIECES RELATIVES A LA SECURITE.
MARQUE ' : PIECS RELATIVE AUX RAYONS X.
This circuit diagram is a standard one, printed circuits
may be subject to change for product improvement
without prior notice.
4
5
21
27K-S100/180/300/400
CK27S10/18/30/40
SCHEMATIC DIAGRAM: CRT, FRONT AV Unit
H
G
):
F
E
D
C
B
A
6
7
1
8
2
9
3
10
4
11
5
22
12
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

27k-s400Ck27s10Ck27s1827k-s180Ck27s30? ck27s4027k-s300

Table of Contents