Theexhaust ductmustendwithan
approved e xhaust venthoodwith
swing outdamper(s). DONOTusean
exhaust venthoodwithmagnetic
latches.
Toavoid exhaust restriction, theoutlet
mustbea minimum of12inches (30
cm)above ground level or anyother
obstructing s urface.
1- Exhaust
air0utlet onthe rear o fthe
appliance
(standard)
2- Exhaust
air0utlet onthe side (optional)
3- Exhaust
air0utlet ontheunderside
ofthe
appliance
(optional)
Special exhaust airconnections must
beobtained f romourcustomer service
foreither c onnection type(see
page 8).
-
Sideairexhaust
-
Bottom airexhaust
A qualified t echnician should change
theexhaust airoutlet t o theoptional
connection l ocation.
Ductwork
Toensure optimum performance, the
ducting system ofthedryer s hould be
asshort a spossible w itha minimum
number o felbows. Yourdryer w illwork
bestwhen theventing system hasas
fewairflowrestrictions aspossible.
Exhaust ducting which is longer t han
recommended mayextend drying time,
cause lintto accumulate andaffect
dryerperformance anddryerlife.
Four-inch ( approx. 100mm) d iameter
ducting should beused. U seeither
rigidmetal o rflexible metal d ucting
material. DONOT useplastic or
non-metal ductwiththisdryer.
DONOTassemble theductwork w ith
screws orfasteners thatextend intothe
duct.They willserve asan
accumulation point f orlint.
Joints should besecured with
aluminium tape.
Alljoints should betighttoavoid leaks.
Themale endofeach ductsection
mustpointaway fromthedryer.
Whether connecting toanexisting
venting s ystem ora newventing
system, make surethatallducting is
clean andfreeoflint.
Themaximum permitted l ength forboth
rigidandflexible metal d uctisshown in
thetablebelow.
Number of Rigid D uct
FlexibleDuct
90°Turns
or Elbows
0
66 ft.
45 ft.
(2011 cm)
(1372cm)
1
56 ft.
36 ft.
(1707 cm)
(1097cm)
2
48 ft.
29 ft.
(1463 cm)
(884 cm)
3
39 ft.
22 ft.
(1189 cm)
(671 cm)
4
30ft.
16ft.
(914 cm)
(488 cm)
Note:
Side and bottom exhaust installations
have a 90 ° turn inside the dryer. To
determine maximum exhaust length,
add one 90°turn to the chart.
More than two 90 ° turns are not
recommended. For best performance,
separate all turns by at least 4 ft. of
straight duct, including distance
between last turn and exhaust hood.
Better
Exhaust
vent hood
Required
parts
The parts required for the exhaust air
system (elbows, lines, exhaust air
outlets) are not included in standard
delivery of the dryer.
Accessories
The parts required for the exhaust air
system can be obtained from customer
service or your local dealer. Please
follow the installation instructions
supplied by the appropriate
manufacturer!
Side exhaust
kit
!
"\\0
part no. WTZ 1265
Note:
The maximum permitted number of 90°
elbows (including this side exhaust kit)
is four!
[_
Special tool for cutting the hole in
prepared side panel is required.
Contact local dealer!