Power Supply Cba Bottom View - Philips 55PFL4909 Service Manual

Hide thumbs Also See for 55PFL4909:
Table of Contents

Advertisement

Power Supply CBA Bottom View

CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F602) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CN601
SA601
CN501
F602
LED-CONT
1
C604
PROTEC1
2
PROTEC3
3
RESET
4
R604
R601
BL-SW
5
L602A
P-ON-H2
6
BL-ADJ
7
ALL+3.3V
8
POWER-GND
9
POWER-GND
10
POWER-GND
11
POWER-GND
12
POWER-GND
13
POWER-GND
14
J607
AMP+13V
15
AMP+13V
16
AMP+13V
17
AMP+13V
18
POWER-GND
19
P-ON-21V
20
P-ON-21V
21
P-ON-21V
22
P-ON-21V
23
C614
C640
C641
C601
D604
D603
C642
T1602
C1621
D1603
C1613
BC1604
J1609
C1622
R1617
J1602
IC1601
J1604
J1612
J1600
5
CAUTION ! :
2.5A 250V
ATTENTION : Utiliser un fusible de rechange de même type de 2.5A, 250V.
C691
R692
D663
R659
IC604
C624
C728
R661
R668
C621
C701
R701
J605
R653
D623
C656
Q602
Q701
J611
J608
D618
C612
T601
J604
R652
J606
C620
C616
BC603
R602
C619
D606
JS601
D607
C1615
COLD
C1626
J1703
R1708
C1702
HOT
R1624
J704
J750
J1601
Q1702
C1623
IC1703
D1605
T1601
B-1704
C1708
Q1601
D1707
TOOL NO.
C1711
8
7
6
5 4 3 2 1
J1608
LC12-55W-USA
BA4GR0F01021
4
3
For continued protection against risk of fire,
replace only with same type 2.5A, 250V fuse.
PROTECT3
PROTECT3
J1409
J500
BL-ADJ
CN501
BL-SW
J501
BL-ADJ
J1403
J503
J502
P-ON_H2
J504
J505
C1418
C1417
IC1401
C1405
RESET
J506
C1414
J507
R756
J1401
R1404
R1415
D715
C654
D658
C655
L1401
PROTECT3
J1400
D653
J1404
C1403
J1405
BL-SW
D655
J1406
J1213
BL-ADJ
C657
J1209
D654
C1340
R1326
C651
IC1301
J1301
C652
J1304
PROTECT3
L1301
J1310
BL-SW
J1309
BL-ADJ
J1302
J1307
J1305
D1205
R1224
R1210
R1220
IC1201
J1306
R1231
IC1702
T1701
C1117
C1118
L1201
J1105
R1115
J1102
R1128
D1101
J1104
C1103
IC1101
L1101
J1107
C725
D712
C723
D711
D710
D706
2
1
10-20
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
GP002
ILED1
2
VLED1
1
J1407
J1210
R1315
J1203
C1303
J1202
R1215
J1300
J1308
J1109
J1101
J701
GP001
BA4GR0F01021

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents