4. Start and stop

4-1. Start and stop engine

Start engine
IMPORTANT
1) Do not keep the engine starter motor running for
more than 10 seconds. If the engine does not start,
keep it cool for one minute before retry. Then,
execute steps (3) - (4).
2) Never turn the main switch to start position while
engine is running.
(1) Open the fuel cock (A).
(2) Put the reversser lever and PTO shift lever in
the "N" position.
(3) Set position control lever in the LOW position.
Make sure that the implement is lowered.
(4) Pull accelerator lever to higher speed position (FA).
(5) Insert key and turn it to "ON" position.
Check pilot lamps on meter panel;
(5) Battery charge pilot lamp is on.
(6) Engine oil pressure pilot lamp is on.
(7) Reverser lever neutral lamp is on.
(6) Turn key switch to "START" position.
(7) As engine starts, immediately release key switch
and it goes back to "ON" position automatically.
When engine starts, battery charge and engine
pressure pilot lamps turn off.
(8) Warm up the engine by running under no-load at
1500 rpm for 5 minutes approximately. Especially if
the temperature is below 0°C, a warm up of at least
10 minutes is required.
(A) Water separator
(B) Fuel cock
(A) Position control lever
(A) Accelerator lever
34
(OP) Open
(C) Reverser lever
(D) PTO shift lever
OPE_EF312T&352T_en.doc