Download Print this page

Operation; System Setup - Polaris DP-20 Quick Start Manual

Web guide controller
Hide thumbs Also See for DP-20:

Advertisement

SYSTEM SETUP

1. Connect the system according to the System Block Diagram and Figure Sheet 1-861, which is
supplied with each system. Refer to Figures 2 and 3 for basic systems cable connections.
2. Apply the proper power to the system.
3. Verify the system is in Manual Mode by pressing the MANUAL key.
NOTE: If Servo Center option is not available go to step #6
4. Switch system to Servo Center Mode by pressing the SERVO-CENTER key.
NOTE: If the guide moves to the center of its stroke press the MANUAL key
5. If the guide moves to one side, then change the Servo Center Polarity
a. Press the MANUAL key to change the system operating mode back to Manual Mode.
b. Press the SETUP key to enter the Setup menus.
c. Select "BASIC" Menu then press ENTER
d. Use the ARROW keys to select "→← Polarity" then press ENTER
e. The current polarity is listed. Press ENTER to allow adjustment of the polarity.
f.
Use the ARROW keys to change the polarity.
g. Press ENTER to save.
h. Repeat step #4
6. Move the actuator to the center of its stroke by pressing the left and right arrows.
7. Thread the web/strip through the system and pull proper tension, if possible.
8. Perform "Sensor Calibration" on the sensor(s) that will provide position feedback for this web/strip. If
two sensors are being used in a center-guiding application they must be calibrated independently.
a. Press the SETUP key to enter the Setup menus.
b. Select "BASIC" Menu then press ENTER
c. Use the ARROW keys to select "CALIBRATION" then press ENTER.
d. Select the proper sensor then press ENTER.
e. Follow the instructions displayed on the LCD Display.
Be sure to use the web to be guided to calibrate sensors.
NOTE: If Manual Configuration is desired go to Step #12
AUTO SETUP CONFIGURATION
9. Place the web/strip in the proper position and then position the sensor(s) to align the center of the
sensor(s) bandwidth with the web/strip to be guided.
10. Perform "Auto Setup" to automatically determine the proper polarity and gain for the system.
a.
Press the SETUP key to enter the Setup menus.
b.
Select "BASIC" Menu then press ENTER
c.
Use the ARROW keys to select "AUTO SETUP" then press ENTER.
d.
Press ENTER begin the Auto Setup. Follow instructions displayed on the LCD Display
11. Switch the system to Automatic Mode by pressing the AUTO key. This initiates the guiding function of
the system.
04/14/2008
to return system to Manual Mode and go to step #7
Page
WEB GUIDE CONTROLLER
QUICK START SETUP MANUAL
3
6
of
POLARIS DP-20

OPERATION

*
*
*
Figure Sheet 2-248

Hide quick links:

Advertisement

loading