Internal view showing switches V12 Software
00007 -6
SW1
ON
1 2
3 4
5 6 7
8
Data OUT
Data OUT
Data OUT
TRA/TRB
TRA/TRB
TRA/TRB
LD1 = Dome RS422/485 out
LD2 = Panasonic RS422/485 in
LD3 = Checksum ERROR or
command for camera out of range
LD5 = Converter Mode
LD6 = Not used
SW4 Output Protocol
VCL - 9600,N,8,1
1 2 3 4 5 6 7 8
PELCO P – 9600,N,8,1
1 2 3 4 5 6 7 8
PELCO P – 4800,N,8,1
1 2 3 4 5 6 7 8
PELCO P – 2400,N,8,1
1 2 3 4 5 6 7 8
DENNARD – 9600,N,8,1
1 2 3 4 5 6 7 8
Panasonic Protocol Converter Manual V10.2 5Mar 09
SW2
Data OUT
Data OUT
Data OUT
TRA/TRB
TRA/TRB
TRA/TRB
SW5/1-4 Camera range
1 - 8
1 2 3 4
33 - 40
1 2 3 4
65 - 72
1 2 3 4
VICON – 4800,N,8,1
1 2 3 4 5 6 7 8
VICON – 9600,N,8,1
1 2 3 4 5 6 7 8
star_
vhd
ON
1 2 3
4 5
6 7
8
Data OUT
Data OUT
Data IN
TRA/TRB
TRA/TRB
2 WIRE
Data OUT
TRA
TRA = A/+
TRB
TRB = B/-
4 WIRE
TRA
TRB
RA
RB
9 - 16
17 - 24
1 2 3 4
1 2 3 4
41 - 48
49 - 56
1 2 3 4
1 2 3 4
73 - 80
81 - 88
1 2 3 4
1 2 3 4
SD MICRO
Must be fitted
SW3
LD 5
ON
1 2
3 4
5 6 7
8
J16
v*.
ON
ON
SW4
SW 5
1 2
3
4 5 6 7
8
1 2 3
4 5 6
7 8
LD 6
PANA
LD 1
CON
LD 2
V**
LD 3
LD4
RS232 DIAGNOSTICS PORT
TA
SW5 Camera Range
TB
RA
RB
1 2 3 4 5 6 7 8
TA
TB
Panasonic Baud
25 - 32
9600
1 2 3 4
57 - 64
1 2 3 4
89 - 96
97 - 99
1 2 3 4
1 2 3 4
Page 6/16
SW3/8
ON = 2 WIRE
OFF = 4 WIRE
SW5/8
19200
8
8