Kenmore 795.851**.900 Service Manual page 16

Electric & gas dryer
Table of Contents

Advertisement

Component
7. Heater
8. Thermistor
9. Motor
10. Gas valve
valve 1
valve 2
11. Igniter
12. Frame Detect
Test Procedure
Measure resistance of the
following terminal
Terminal: 1 (COM) - 2
1
Terminal: 1 (COM) - 3
2
Terminal: 2 - 3
3
Measure resistance of terminal
to terminal
Temperature condition:
58¡F ~ (10~40¡C)
58¡F ~ 104F (10~40¡C)
Measure resistance of the
following terminal
Valve 1 terminal
1
Valve 2 terminal
2
Measure resistance of terminal
to terminal
Measure resistance of terminal
to terminal
Open at 370¡F ((Maximum)
1
Close at 320¡F
2
Check result
Resistance value: 10
1
Resistance value: 10
2
Resistance value: 20
3
Resistance value: 10
Resistance value: > 2.3k
1
Resistance value: > 2.3~2.7k
2
Resistance value: 100~800
Resistance value
1
Resistance value < 1
2
15
Remark
¥ Electric type
¥ Heater case -
Hi limit
¥ Electric type
¥ See Page 13
¥ Gas type
¥ Gas type
¥ Gas type

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.921**.900

Table of Contents