4. TESTING PROCEDURE
3. Boiling control lever adjustment
Such a mechanical operation as center thermostat goes up and down is used to turn on
and off the micro-switch. Check and adjust this relationship as shown below.
When the boiling switch is turned on.
Checking
The auxiliary lever presses the push-
button (The "WARM" lamp comes on.)
Adjusting
To gain the above relationship, adjust the auxiliary lever by bending it with
long nose pliers.
When the boiling switch is turned off.
The auxiliary lever does not press
the push-button (The "COOK" lamp
comes on.)
10