Technical data
Flow rates / Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Valve for Zone washing
Spray arm lower
Sprayarm upper
Ceiling rotor
Electrical data
Base data
Voltage
Frequency
Total power
Fuse
Motor
Spray pump motor
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Heating
1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
Whirlpool Europe
Customer Service
208
lmp/l
~ 70
l/min
16
l/min
1.1
m
4.5
l/min
30
l/min
33
l/min
27
l/min
10
l/min
220/230
V
50
Hz
2.0-2.2
kW
10
A
220/230
V
160
W
81
44
4
F
220/240
V
30
W
146
220/230
V
1.87/2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
85
˚C
ADP 962/3 WHM
8542 962 10410
Potentiometer
Points of measurement:
1 (black) to 2 (middle)
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Water valves
Double valve at inlet hose
Voltage
Frequency
Resistance
Regenerating valve
Voltage
Frequency
Resistance
Valve for zone washing
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reedcontact
flow meter
salt control
rinse aid control
NTC
15 ˚C
20 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
29.06.1999 / Page 3
Doc. No: 4812 718 14566
0.0
kΩ
0.5
kΩ
1.0
kΩ
1.4
kΩ
1.8
kΩ
2.3
kΩ
2.6
kΩ
220/240
V
50/60
Hz
2
kΩ
220/240
V
50/60
Hz
3.13
kΩ
220-240
V
50/60
Hz
4
kΩ
220/240
V
50/60
Hz
1.5
kΩ
75
kΩ
62
kΩ
43
kΩ
28
kΩ
19
kΩ
13
kΩ
9
kΩ
6
kΩ
5
kΩ