Floating - Symmetry; Vca - Offset; Adjusting The Meter Instruments; Adjusting The Fans - Electro-Voice P3000 Service Manual

Hide thumbs Also See for P3000:
Table of Contents

Advertisement

Adjusting the idling current has to be performed at normal room temperature. In case the power amplifier had
previously been operated, it has to be given several hours to cool off.

4.2. FLOATING - SYMMETRY

Immediately after setting the idle current, a symmetry check of the floating voltage has to be performed. The
power amplifier has to be operated in idling condition. DC-volt meters have to be connected between the
measuring points 1 - 2, and 2 - 3. Using the FLOATING-trim potentiometers that are located on the printed
board assembly 86207/86211, the floating voltage is set symmetric to the ground potential. Not the actual
voltage value is relevant but the symmetry of the + floating voltage and the - floating voltage to the ground
potential.
Setting
FLOTING SYMMETRIE A
FLOTING SYMMETRIE B

4.3. VCA - OFFSET:

Rhythmically open and short-circuit the service switch S101 respectively S201 which are located on the printed
board assembly 86207/86211. Use VR101 respectively VR201 to adjust the power amplifier outputs to their
minimum offset (with oscilloscope to minimal peak value or to the audible minimal volume of the interfering
pulse).
Instead of using the service switch, it is also possible to employ the service connector with short-circuited pins
CNASERV 2 and CNASERV 3 for the power amplifier A, or short-circuited pins CNBSERV 2 and CNBSERV
3 for the power amplifier B.

4.4. ADJUSTING THE METER INSTRUMENTS

level control set all the way to its clockwise position
f = 1 kHz
Feed the signal to the inputs A or B so that the IN-LED just lights (U(E) approx. -34 dBu). Adjust the OUT-LED
to approximately the same brightness, using the trim potentiometers VR600 respectively VR601 which are
located on the printed board assembly 86207/86211.

4.5. ADJUSTING THE FANS

Close the service switch S001 on the printed board assembly 86207/86211 or insert a bridge between CNBSERV
5 and CNBSERV 6. Adjust the voltage at CNBSERV 4 to 27.5 V (DC), using the VR700. Switch the service
switch back to normal or detach the bridge.
4.6. GAIN SELECTION:
The power amplifier's input sensitivity can be set using the jumpers J11 ... J13 or J21 ... J23 which are located
on the printed board assembly 86207/86211. The stated values for the input sensitivity or gain are always
referenced to the level control being set to its fully clockwise position.
CHANNEL A
J11
J12
J13
When shipped, the input sensitivity is set to a value of 0 dBu.
5.
Function test
5.1. OUTPUT - offset voltage
DC-voltage measuring at the loudspeaker outputs CHANNEL A/B with U(DC) ≤ ±10 mV.
5.2 LIMITER
5.2.1. Attenuation test
Both channels separately driven with a 1 kHz signal up to U(A) = 89 V (without load). Increase the input voltage
by 10 dB. The LIMITER LED lights and the output voltage ascents by approx. 0.5 dB to 91 volts, with slight
Measuring
Measuring
point 1
point 2
CNSERV 8
CNSERV 7
AMP-A
AMP-A
CNSERV 8
CNSERV 7
AMP-B
AMP-B
CHANNEL B
J21
J22
J23
4
Measuring
U(DC)
point 3
ca. ± 67V
CNSERV 9
AMP-A
ca. ± 67V
CNSERV 9
AMP-B
SELECTION
Input Sensitivity 0 dBu
Input Sensitivity +6 dBu
Gain +26 dB
Trim
potentiometer
VR102
VR202

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P3000 series

Table of Contents