Cleaning the moisture
sensor
The moisture sensor has to be cleaned
because a fine layer of transparent
build up is deposited on the sensors.
This deposit can easily be removed by
wiping the sensors (the two bars next
to the filter) with a cloth and a little white
vinegar.
Use white vinegar only!
Clean the moisture sensor once
a month.
Do not use steel wool or abrasive
d
materials.
26
Cleaning the bearing
shield
Over time, fluff from the drying process
collects in the bearing shield.
This fluff can be easily removed using
your vacuum cleaner, at least once
a month.

Change the light bulb

The dryer light turns on inside the drum
when you open the door.
To change the light bulb:
q
Set program selector to Off.
Pull out power supply plug.
q
q
Open the dryer door. The light
is located on the upper left side
of the door opening
q
Loosen the screw of the cover and
open the cover.
Turn bulb counterclockwise.
q
Replace the bulb with a new
appliance bulb (only obtainable
through customer service).
q
Replace the cover and secure with
the screw.
q
Replace the mains plug into the
socket.