Standard Plus Temp; Pre-Spin Mops; Chemo Thermal Dis; Thermal Disinfection - Miele PW 5064 MopStar 60 Operating And Installation Instructions

Hide thumbs Also See for PW 5064 MopStar 60:
Table of Contents

Advertisement

Settings/Supervisor level menu

Standard plus temp.

The pre-set temperature can be
changed in the Standard plus
programme. There are 4 different
temperatures to choose from.
40°C
60°C (factory default setting)
70°C
90°C

Pre-spin mops

In the Standard, Standard plus,
Thermal disinfection and Chemo
thermal disinfection programmes, wet
mops are spun briefly at the start of
the programme to remove surplus
water.
The machine is delivered with this
option activated.
66

Chemo thermal dis.

The pre-set disinfection process can
be altered in the Chemo thermal
disinfection programme. There is a
choice of 4 temperatures with
corresponding holding times.
40°C / 20 min
60°C / 20 min
70°C / 10 min (factory default setting)
71°C / 25 min

Thermal disinfection

The pre-set disinfection process can
be altered in the Therm. disinfection
programme. There is a choice of 2
temperatures with corresponding
holding times.
75°C / 10 min
85°C / 15 min (factory default setting)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents