This appliance is for use with natural gas (g20). when converted using conversion
kit no. 0595241 this appliance is for use with propane gas (g31). (25 pages)
Inset live fuel effect gas fire, fitted with one of the following fascia. amour, aspect, aspect glass, eclipse, fascination, landscape, serenity, tranquility or visia (42 pages)
Page 2
Installer Guide and should not be fitted directly on to a carpet. Baxi Fires Division, Erdington, Birmingham B24 9QP Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication...
OWNER GUIDE LIST OF CONTENTS Section Page SAFETY GAS CONSUMPTION OPERATING YOUR FIRE How to light your fire. How to turn your fire off. Lighting with a taper. The flame sensing and flue blockage safety system. CLEANING YOUR FIRE Metal parts. Ceramic fuel effect and burner compartment rear wall.
OWNER GUIDE SAFETY IF YOU SMELL GAS DON’T SMOKE. EXTINGUISH ALL NAKED FLAMES. DON’T TURN ELECTRICAL SWITCHES ON OR OFF. TURN OFF THE GAS SUPPLY AT THE METER. OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. IMMEDIATELY CALL THE GAS EMERGENCY SERVICE – SEE YOUR LOCAL TELEPHONE DIRECTORY.
Page 5
OWNER GUIDE Do Switch the fire and fan off and allow to cool completely before attempting to clean, service, etc. This appliance retains heat for some time after it has been switched off Do always use a fireguard complying with BS 8423 for the protection of young children, the elderly or infirm.
Has a minimum natural gas input of 2.3kW (Gross) Has a minimum natural gas output of 1.1kW Model 661 when converted using kit number 0595221 Has a maximum propane gas input of 6.1kW (Gross) Has a maximum propane gas output of 3.15kW Has a minimum propane gas input of 3.8kW (Gross)
OWNER GUIDE Slightly depress the knob and turn it to "LOW". Release the knob. Within a few seconds the main burner should light at its low setting. Slightly depress the knob and gradually turn it towards "HIGH" until the burner is at your desired setting.
OWNER GUIDE does not clear the flue, the pressure detector will shut off the gas supply. The small light on the control box will light each time the ‘boost’ speed is used. If the flames go out, or if for any reason the fire is turned off, always wait at least 3 minutes before attempting to relight.
OWNER GUIDE left inside or attached to this guide by the installer. Burner. Remove any soot or other foreign matter from the burner with a dry soft brush. Be careful not to brush any particles into the open slots. Remove any particles from the slots with a vacuum cleaner fitted with a soft brush attachment.
OWNER GUIDE Mains cable. If the mains cable becomes damaged it must be replaced with an authorised replacement part. It must be replaced by a CORGI registered installer. Servicing. In the United Kingdom servicing must be carried out either by a CORGI registered installer.