Noise/Vibration Information
Sound emission values determined according to
EN 50636-2-107.
Typically the A-weighted noise levels of the product are:
Sound pressure level 64 dB(A); sound power level 72 dB(A).
Uncertainty K =2.74 dB.
Explanation of Installation Guide
(see pages 3–14)
Action
Delivery scope/unpacking product
Position the docking station
Thread wire through base plate
Connect first end of perimeter wire
Fix docking station to the ground
Lay out perimeter wire
Extend perimeter wire
Lay out additional area with perimeter
wire
Connect second end of perimeter wire 11
Clip on protective cover of docking
station
Install power supply
Docking station indicates power on
Plug in isolator key
Charge battery by putting the machine
into docking station
Welcome screen = Refer to manual
Lift up and carry the machine
Set height of cut
Logicut Intelligent Cutting
Cleaning
Maintenance
Lawn Preparation
Remove stones, loose pieces of wood, wire, live mains cables
and other foreign objects from the cutting area.
Make sure that the cutting area is even and has no ditches,
grooves and steep slopes above 20° that are clear obstruc-
tions for the machine.
Cut the main area of the lawn with a conventional mower to a
max. height of 40 mm and the perimeter wire area to a max.
height of 20 mm.
Installation
For a video guide on how to install the Indego please visit
www.bosch-indego.com or use the following QR-Code.
Bosch Power Tools
Select a position for the docking station, horizontally levelled
and out of direct sunlight.
Note: The docking station must be positioned on the wire at
an outer edge of the cutting area. It cannot be positioned by
the side of a shed or workshop that appears as an island with-
Figure
Page
in the cutting area.
1
4
Make sure that the docking station is placed beside the cut-
2 – 4
4 – 6
ting area with a straight 1.5 m track in front of the docking sta-
5
6
tion and a straight 1 m track behind. Whilst stood in the grass
area to be cut it is important that the docking station charging
6
6
pins point to the left. (see figure 2)
7
6
Note: If the docking station is positioned with the charging
8
7
pins pointing either into the grass area or pointing to the right
9
8
the Indego will not run correctly.
Pull the wire end through the front hole of the base plate and
10
8
straight through the wire duct and the rear hole. Fix the wire
with a peg inline with the hole. Cut off insulation carefully and
9
connect the wire to the right hand (red) terminal. (see
figures 5 – 6)
12
9
Fix the docking station with 4 supplied fixing pins to the
13
10
ground. (see figure 7)
14
10
Lay out the perimeter wire anti-clockwise and flush to the
15
10
ground. Observe the minimum distances from lawn edges,
steps, walls, ponds, etc. Use the spacing guide. (see figure 8)
16
11
Note: The cable should be positioned so that the Indego will
17
11
not be more than 16 m away at anytime.
18
12
If the working area borders against a flat path or surface that
is level with the lawn the Indego will be able to run over it. In
19
12
such cases the perimeter wire should be positioned right up
20
13
to the edge of the lawn.
A
14
B
14
to a maximum depth of 5 cm. It is recommended to mark out
permanent objects within the garden. This will prevent the In-
dego colliding with the object and reduce wear on the shell.
Objects on the lawn below 6 cm height e.g. trees, ponds, flow-
er beds etc. must be delimited in a clockwise direction. The
lines to and from these zones may not cross but the wire
should be touching. (see figure 8)
20-25cm
Fix the wire with the first peg next to the docking station, ten-
sion and fix with pegs at a distance of approx. 50 cm. (see
figure 8)
Continue the loop and bring the wire to the back of the dock-
ing station and inline with the other end of the wire. Fix the
second end of the wire also with the peg. Perimeter wire and
peg should be installed inline. Shorten the wire, cut off insula-
tion carefully and connect the wire to the left hand (black) ter-
minal. (see figure 11)