3. LENS CONTROL
(1) OIS ADJUSTMENT
- When you adjust the OIS function which have a OIS lens, you can adjust it.
- How to adjust
After combine the lens, enter the tester mode. Select the LENS CONTROL → OIS ADJUSTMENT → Press the OK button.
* Caution : Do not shake the camera when adjust it.
(2) ZOOM WIDE SET, ZOOM TELE SET
- When you adjust the position of zoom position, you can use it.
(After changing the PCB inside the lens or disassemble the mount, you must adjust it.)
- How to adjust
After combine the lens, enter the tester mode. Select the LENS CONTROL → ZOOM WIDE SET
→ Locate the zoom position to the Wide. → Select OK (In case of Tele, vise versa)
* Caution : Do not shake the camera when adjust it.

5-3 CIS TILT Adjustment

■ If you change or disassemble the CMOS ASS'Y, you must do the CMOS Tilt adjustment.
<How to Adjust>
1. Prepare CIS Tilt adjustment tools. (Kyoritsu (RSM-5000))
2. After pressing the Start button, Tilt adjustment procedure finished automatically.
3. After completing the adjustment, please bonding 3 screws and fix it as below.
<Adjustment Result>
It can be adjust below 10 between MOUNT and CMOS ASS'Y.
SAMSUNG
This Document can not be used without Samsung's authorization
The screw of CMOS Tilt adjustment.
Fig. 5-2
Adjustment
5-3