Heavy Duty And Normal Duty Ratings; Heavy Duty And Normal Duty Ratings - YASKAWA J1000 Technical Manual

Compact v/f control drive
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

A.1 Heavy Duty and Normal Duty Ratings
A.1 Heavy Duty and Normal Duty Ratings
The capacity of the drive is based on two types of load characteristics: Heavy Duty (HD) and Normal Duty (ND).
Refer to Selecting the Appropriate Load Rating on page 180
capacity ratings are listed on the following pages.
Setting Parameter
Rated Output Current
C6-01
HD Rating
0: Heavy Duty
varies by model
ND Rating
1: Normal Duty
(default)
varies by model
<1> The following pages list information on rating changes based on drive model.
• HD and ND: HD refers to applications requiring constant torque output, while ND refers to applications with
TERMS
TERMS
variable torque needs. The drive allows the user to select HD or ND torque depending on the application. Fans,
pumps, and blowers should use ND (C6-01 = 1), and other applications generally use HD (C6-01 = 0).
• Swing PWM: Swing PWM equivalent to a 2 kHz audible noise. This function turns the motor noise into a less
obtrusive white noise.
Note:
Differences between HD ratings and ND ratings for the drive include rated input and output current, overload capacity, carrier frequency,
and current limit. The default setting is for ND (C6-01 = 1).
180
Table A.1 Selecting the Appropriate Load Rating
150% rated output current for 60 s
<1>
120% rated output current for 60 s
<1>
varies by model
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com
for the differences between HD and ND. Specifications for
Overload Tolerance
Default Carrier Frequency
8/10 kHz
varies by model
2 kHz, Swing PWM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents