Trigger
Trigger
Control
Trigger Function
Pressing the Shift Trigger key generates an immediate trigger
Trigger Control Functions
INIT:IMMED
Initiate trigger immediately
INIT:CONT ON | OFF
Initiate trigger continuously
TRIG:SOUR BUS | EXT
Select transient trigger source
TTLT | IMM
DELAY <value>
Set trigger delay in seconds
ABORT
Abort all trigger sequences
SYNC:SOUR PHASE | IMM
Select synchronous trigger source
SYNC:PHASE <value>
Set synchronous phase reference
Current
Voltage
Current Functions
CURR:LEV <value>
set immediate rms current limit
CURR:PEAK <value>
set immediate peak current limit
CURR:PEAK:T <value>
set triggered peak current limit
CURR:PEAK:M FIXED | STEP
select the peak current limit mode
PULSE | LIST
Voltage Functions
VOLT <value>
set immediate ac output voltage
VOLT:T<value>
set triggered output voltage
VOLT:M FIXED | STEP
select the voltage mode
PULSE | LIST
RANGE 150 | 300
set the voltage range
OFFSET <value>
set immediate dc offset voltage
OFFSET:T<value>
set triggered dc offset voltage
OFFSET:M FIXED | STEP
select the dc offset voltage mode
PULSE | LIST
SLEW <value>
set voltage slew in V/sec
SLEW:T<value>
set triggered voltage slew in V/sec
SLEW:M FIXED | STEP
select the voltage slew mode
PULSE | LIST
OFF:SLW <value>
set dc offset slew in V/sec
OFF:SLW:T<value>
set triggered dc offset slew in V/sec
OFF:SLW:M FIXED | STEP
select the dc offset voltage slew
PULSE | LIST
mode
ALC INT | EXT
select the voltage sense source
ALC:DET RTIME | RMS
select the voltage sense detector
Phase
Freq
Phase Functions
PHASE <value>
set immediate output phase
PHASE:T <value>
set triggered output phase
PHASE:M FIXED | STEP
select the phase mode
PULSE | LIST
Freq Functions
FREQ <value>
set immediate output frequency
FREQ:T<value>
set triggered output frequency
FREQ:M FIXED | STEP
select the frequency mode
PULSE | LIST
SLEW <value>
set frequency slew in Hz/sec
SLEW:T<value>
set triggered frequency slew Hz/sec
SLEW:M FIXED | STEP
select the frequency slew mode
PULSE | LIST

Quick Start Guide

4
3
3
3
4
4
4
2, 4
3
3
3
4
4
4
3
3
3
3
4
4
4
Shape
Shape Functions
SHAPE
SINE |SQUARE
set immediate shape
CSIN | <user>
SHAPE:T
SINE |SQUARE
set triggered shape
CSIN | <user>
SHAPE:M FIXED | STEP
set shape mode
PULSE | LIST
CLIP <value>
set clipping level
List
Pulse
List Functions
COUNT <value>
DWEL:<index> <value>
FREQ:<index> <value>
FSLW:<index> <value>
IPK:<index> <value>
OFFS:<index> <value>
OSLW:<index> <value>
PHASE:<index> <value>
SHAP:<index> SINE | SQUARE
CSIN | <user>
STEP ONCE | AUTO
TTLT:<index> ON | OFF
VOLT:<index> <value>
VSLW:<index> <value>
Pulse Functions
WIDTH <value>
COUNT <value>
DCYCLE <value>
PER <value>
HOLD WIDTH | DCYCLE
& Index
% % % % Index
! ! ! !
" " " "
& % Index Functions
These are Shift Index keys which are used to scroll through indexed
functions. Press these keys to step through integers 0 through 50 for a
harmonic list, or 0 through 99 for list points. Hold down these keys to
rapidly access any harmonic or list point.
& % Functions
These keys let you move through the choices in a command list.
Command lists are circular; you can return to the starting position by
continuously pressing either key.
This key applies to 3-phase ac sources only.
Phase
Pressing this key successively selects phase 1
Select
first, followed by phase 2, phase 3, and then all
three phases.
Output
This key toggles the output on and off. When off,
On/Off
the ac source output is disabled and the Dis
annunciator is on.
number of times a list repeats
list of output dwell times
list of output frequencies
list of output frequency slew rates
list of output peak current limits
3
list of dc output voltages
3
dc offset voltage slew rate list
3
list of output voltage phase angles
4
list of output waveform shapes
set response of list to triggers
set trigger out pulse list
list of ac output voltages
4
list of output voltage slew rates
4
set the pulse width
set the number of output pulses
set the pulse duty cycle
set the pulse period count
set parameter that is held constant
19