Bosch AutoDome Junior HD VJR Series Operation Manual
Bosch AutoDome Junior HD VJR Series Operation Manual

Bosch AutoDome Junior HD VJR Series Operation Manual

Hide thumbs Also See for AutoDome Junior HD VJR Series:
Table of Contents

Advertisement

AutoDome Junior HD Series
VJR Series
en
Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch AutoDome Junior HD VJR Series

  • Page 1 AutoDome Junior HD Series VJR Series Operation Manual...
  • Page 3: Table Of Contents

    Overview of Features 11.2 System Requirements 11.3 Connecting the AutoDome Junior HD to the PC 11.4 Configuring the AutoDome Junior HD Camera 11.4.1 Changing the Network Settings 11.5 The Livepage Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 4 Pixel Counter 12.32 Advanced Mode: Recording 12.33 Storage Management 12.34 Recording Profiles 12.35 Retention Time 12.36 Recording Schedule 12.37 Recording Status 12.38 Advanced Mode: Alarm 12.39 Alarm Connections 12.40 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 5 Troubleshooting 14.1 AutoDome Junior Operation and Control 14.2 LED Diagnostics Preventive Maintenance BVIP Firmware Updates 16.1 Upgrading the AutoDome IP or HD 16.2 Beginning the Firmware Update Process Index Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 6: Safety

    For units supplied by an external power source, use only the recommended or approved power supplies. For limited power source units, this power source must comply with EN60950. Substitutions may damage the unit or cause fire or shock. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 7: Safety Precautions

    16. Attachments, changes, or modifications - Only use attachments/accessories specified by the manufacturer. Any change to or modification of the equipment not expressly approved by Bosch could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
  • Page 8: Important Notices

    2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 9 Please dispose of these units at an environmentally compatible recycling facility, in line with European Directive 2002/96/EC. Environmental statement - Bosch has a strong commitment to the environment. This unit has been designed to respect the environment as much as possible.
  • Page 10 Au besoin, l’utilisateur consultera son revendeur ou un technicien qualifié en radio/télévision, qui procédera à une opération corrective. La brochure suivante, publiée par la Commission fédérale des communications (FCC), peut s’avérer utile : « How to Identify and Resolve Radio- 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 11 UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT. Copyright This user guide is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 12: Customer Support And Service

    | Safety AutoDome Junior HD Series Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers Repair Center Telephone: 800-566-2283 Fax: 800-366-1329 E-mail: repair@us.bosch.com...
  • Page 13: Unpacking

    This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the Parts List are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative.
  • Page 14: Description

    Refer to Using the IP Interface, page 47 for software and infrastructure requirements for an AutoDome Junior IP or HD installation. This installation should be made by qualified service personnel and conform to the National Electrical Code and applicable local codes. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 15 AutoDome Junior HD Series Description | en Notice! A grounded conduit is required in order to meet the EMC Regulation Requirements. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 16: Installing A Surface Mount

    The following instructions detail the preparation necessary to prepare the surface and the steps to install a Surface Mount. Determine a secure location for the surface mount dome. ø 175.0 (6.89) 166.9 (6.57) R64.2 (2.53) Figure 4.1: Indoor Surface Mount Dimensions 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 17 Skip to Installing the Camera to the Mounting Plate, page 18, to continue the installation. See also – Preparing the Surface Mount for an Indoor Installation, page 17 – Parts List, page 13 – Parts List, page 13 Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 18: Installing The Camera To The Mounting Plate

    Unlock the single safety locking screw on the base of the unit using the user-supplied Allen wrench. Figure 4.4: Unlock Safety Locking Screw Plug the matching connectors from the camera into the mating connectors from the ceiling. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 19 (Item 3) to the right of the safety locking screw (item 2). Note: Do not loosen the three brass buttons (item 4). These brass buttons engage the slotted tabs (item 5) on the mounting plate. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 20 Slotted Tab (total of three on mounting plate) Rotate the camera approximately 15 degrees in a clockwise direction to lock firmly into place, as shown in the next illustration. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 21 Figure 4.7: Attach Dome to Mounting Plate Vertical tab Secure the safety locking screw with the user supplied locking torx wrench (T-10). See also – Preparing the Surface Mount for an Indoor Installation, page 17 Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 22: Installing A Wall Mount

    220.4 (8.68) 291.0 (11.46) Figure 5.1: Wall Mount Dimensions Fit a user-provided metal single-gang junction box to the wall. Attach a grounded metal conduit to the junction box clamp. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 23 Notice! The metal junction box and mounting surface must be capable of supporting a maximum load of 11.33 kg (25 pounds). Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 24: Installing The Camera To The Mounting Plate

    Connect the mating connectors with the flying leads to the user supplied wiring (see the Preparing the Wiring, page 39 for wiring information). Unlock the single safety locking screw on the base of the unit using the user-supplied Allen wrench. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 25 AutoDome Junior HD Series Installing a Wall Mount | en Figure 5.4: Unlock Safety Locking Screw Plug the matching connectors from the camera into the mating connectors from the ceiling. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 26 (Item 3) to the right of the safety locking screw (item 2). Note: Do not loosen the three brass buttons (item 4). These brass buttons engage the slotted tabs (item 5) on the mounting plate. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 27 Figure 5.6: Tab/Slot Alignment Detail Vertical Tab (on mounting plate) Locking Screw Recessed Slot (on dome housing) Brass Button (total of three on housing) Slotted Tab (total of three on mounting plate) Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 28 Figure 5.7: Attach Dome to Mounting Plate Secure the safety locking screw with the user supplied locking torx wrench (T-10). Pull excess wire back into the mount tube. Confirm that the housing is electrically grounded. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 29: Installing A Recessed Mount

    AutoDome Junior HD Series Installing a Recessed Mount | en Installing a Recessed Mount Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 30: Installing A Pipe Mount

    Determine a secure hard surface location for the ceiling pipe mount (supplied separately). 88.8 (3.5) 88.8 (3.5) 768.2 (30.24) 3/4-14 NP 561.2 SM Threads (22.09) Ø11.2 (4x) (0.44) 461.2 (18.16) Ø175.0 (6.89) Figure 7.1: Pipe Mount Dimensions 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 31 The fasteners and mounting surface must be capable of supporting a maximum load of 11.33 kg (25 pounds). Pull the wires from the pipe, starting at the flange end. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 32 | Installing a Pipe Mount AutoDome Junior HD Series Figure 7.3: Attach Pendant Pipe Mount to Ceiling 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 33 Select a rigid mounting location to prevent excessive vibration to the AutoDome Junior Camera. Attach user supplied ground lug. Align holes of mounting plate (supplied with dome) with dome mounting cap and attach with the three (3) screws supplied (Figure 1.9). Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 34 | Installing a Pipe Mount AutoDome Junior HD Series 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 35: Installing The Camera To The Mounting Plate

    Connect the mating connectors with the flying leads to the user supplied wiring (see the Preparing the Wiring, page 39 for wiring information). Unlock the single safety locking screw on the base of the unit using the user-supplied Allen wrench. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 36 (Item 3) to the right of the safety locking screw (item 2). Note: Do not loosen brass mounting buttons. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 37 Figure 7.6: Tab/Slot Alignment Detail Vertical Tab (on mounting plate) Locking Screw Recessed Slot (on dome housing) Brass Button (total of three on housing) Slotted Tab (total of three on mounting plate) Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 38 Figure 7.7: Attach Dome to Mounting Plate Secure the safety locking screw with the user supplied locking torx wrench (T-10). Pull excess wire back into the mount tube. Confirm that the housing is electrically grounded. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 39: Preparing The Wiring

    Ethernet input. Ensure that the camera receives power from only one source. Refer to Ethernet Connection (IP models), page 40, for more information about connecting Power over Ethernet. Notice! Use certified / Listed Class 2 power supply transformer only. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 40: Power Connections To Indoor Cameras

    The heater in an outdoor AutoDome Junior HD unit accepts power only from a 24 VAC power source. The heater cannot be powered via the Power-over-Ethernet + (IEEE 802.3at, class 4) standard. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 41 Cable Type CAT-5E or CAT 6 Ethernet Maximum Distance 100 m (328 ft) Bandwidth 10 Base-T/100 Base-TX PoE+ (indoor models only) IEEE 802.3at, class 4 standard Terminal Connector RJ45, Female Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 42: Audio, Alarms And Relay Connections

    You can configure alarms 1 through 2 as Normally Open (N.O.) or Normally Closed (N.C.) alarms. 9.2.1 Connecting a Normally Open Alarm Connect the alarm to the appropriate input (1 through 2) and ground at the AutoDome Junior. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 43: Connecting A Normally Closed Alarm

    Ground (Ref. #4) Green From the AutoDome Junior HD Settings page select Interface>Alarm Inputs. Refer to Configuring the AutoDome Junior HD, page 61, for directions about accessing the Settings page. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 44: Alarm Outputs

    The AutoDome Junior is capable of receiving line input audio signals and transmitting it over a network. The audio signal is transmitted one-way and in sync with the video signal. Refer to Basic Mode: Audio, page 64. Audio Line Input Specifications 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 45 Internal gain level adjustment is available Wire Specifications Wire Type Coax (recommended) Distance 10 m (33 ft) Gage 22 AWG Shield Bare copper braid: 95% coverage Center conductor Stranded bare copper Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 46: Getting Started

    If you are using an AutoDome Junior IP or HD model, refer to Using the IP Interface, page 47. Warning! Before powering the dome on, remove the clear protective plastic sheet on top of the bubble. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 47: Using The Ip Interface

    (Intranet) or on the Internet. You can also update the firmware, load device configurations, store configuration settings, and copy these settings from one camera to another. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 48: System Requirements

    You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer. If you choose to use a computer running Microsoft Internet Explorer or any of the Bosch software, the computer must conform to the following minimum requirements: –...
  • Page 49: Connecting The Autodome Junior Hd To The Pc

    IP Connection Network Switch Computer Notice! You can also use the Bosch Configuration Manager utility to configure the network settings for an AutoDome Junior IP or HD camera. Go to www.boschsecurity.com to download the Configuration Manager software and Operating Manual. 11.4 Configuring the AutoDome Junior HD Camera To operate the camera in your network you must assign it a valid network IP address.
  • Page 50: Changing The Network Settings

    Contact your local network administrator for a valid IP address, Subnet Mask, and a Gateway IP Address. Using the Configuration Manager Configuration Manager is an optional network utility provided on the Bosch Security Systems Web site. Use the Configuration Manager Manual to make any configuration changes. Notice! Depending on the PC network security settings, the user may have to add the new IP address to the browser’s trusted sites list for the AutoDome Junior HD controls to operate.
  • Page 51 Notice! Click the Help on this page? link if you need more information. Click the Set button to save the settings. Launch another instance of Microsoft Internet Explorer. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 52: The Livepage

    While discovery is executed, gaps might be shown in places which the discovery has not yet reached. The gap will automatically be replaced by the true video, as soon as the correct information is available. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 53 If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each AutoDome Junior IP can have up to 25 Web browser connections or up to 50 connections via the Bosch Video Management System. Protected AutoDome Junior IP...
  • Page 54 1, 2, 3, 4, directions. 5, 6 and 7. Zoom out. Moves the camera to pre-set shot numbers 1, 2, 3, 4, 5 and 6. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 55 If you want to delete the entries, click the delete icon in the top right-hand corner of the relevant field. If you want to view a detailed log, click the icon in the top right-hand corner of the relevant field. A new window will open. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 56: Entering A Keyboard Control Command

    Click the Focus or Iris button to select a menu item. To Set a Preset Shot: Preset shots (or scenes) are camera positions that are saved in memory for future use. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 57: Operation

    The Web browser opens a new page with the configuration menu. Click the Advanced Link; then click the Camera link, located in the left pane of the Settings window. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 58: Saving Snapshots

    To change the storage location for the recorded video, navigate to the Livepage settings on the Settings page. Notice! You can play back saved video sequences using the Player from Bosch Security Systems, which can be installed from the product CD supplied. Image Resolution Sequences are saved at the resolution that has been preset in the configuration for the encoder (see Basic Mode: Network, page 63).
  • Page 59: The Recordings Page

    Leap to the start of the active video sequence or to the previous sequence Leap to the start of the next video sequence Slide Control You can use the slide control to control playback speed. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 60 Bookmarks are only valid while you are in the Recordings page; they are not saved with the sequences. As soon as you leave the page all bookmarks are deleted. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 61: Configuring The Autodome Junior Hd

    Bosch Video Management Systems programs. The device name is used for the remote identification of a unit, in the event of an alarm for example.
  • Page 62: Basic Mode: Date/Time

    The unit polls the time signal automatically once every minute. Enter the IP address of a time server here. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 63: Basic Mode: Network

    If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the AutoDome Junior HD. Certain application (VIDOS, Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the unit. If you use these...
  • Page 64: Basic Mode: Audio

    You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 65: Advanced Mode: General

    VIDOS or Bosch Video Management Systems program. Enter a unique, unambiguous name for the camera in this field. You can use both lines for this.
  • Page 66: Date/Time

    If there are empty lines at the bottom of the table, for example after deletions, you can add new data by marking the row and selecting required values from the list fields. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 67: Display Stamping

    In the Position (XY) fields, enter the values for the desired position. Alarm message Enter the message to be displayed in the image in the event of an alarm. The maximum text length is 31 characters. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 68: Advanced Mode: Web Interface

    If you want to use the original graphics again, simply delete the entries in the Company logo and Device logo fields. JPEG interval You can specify the interval at which the individual images should be generated for the M- JPEG image on the Livepage. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 69: Livepage Functions

    If necessary, click Browse to find a suitable directory. 12.16 Logging Save event log Check this option to save event messages in a text file on your local computer. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 70: Advanced Mode: Camera

    Encoding interval: 30.00 ips – High Resolution 2 Target bit rate: 1500 kbps Maximum bit rate: 3000 kbps Encoding interval: 30.00 ips – Low Bandwidth Target bit rate: 700 kbps 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 71 If the value entered here is too low, it will automatically be adjusted. Video resolution Here you can select the desired resolution for the video image. The following resolutions are available: Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 72: Encoder Streams

    HD stream options: – H.264 MP 720p25/30 Fixed – H.264 MP 720p30/60 Fixed – H.264 MP 1080p Fixed SD stream options (use these options if a second H.264 stream is allowed): 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 73 Frame rate: Select one of the following frame rates: 5, 10, 15, 20, 25, or 30 ips. – Picture quality: his setting allows you to adjust the image quality. Use the slide bar to choose a quality between Low and High. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 74: Privacy Masks

    AGC (default): electronically brightens dark scenes, which may cause graininess in low light scenes. – Fixed: no enhancement. This setting disables the Max. Gain Level option. If you select this option, the AutoDome Junior HD makes the following changes automatically: 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 75: Lens Settings

    One Push (default): activates the Auto Focus feature after the camera stops moving. Once focused, Auto Focus is inactive until the camera is moved again. – Auto Focus: Auto Focus is always active. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 76: Ptz Settings

    1 and 60 (expressed in degrees), inclusive. The default setting is 30. Inactivity Selects the time period the dome must be not controlled until the inactivity event will be executed. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 77 Note 1: You can save a total of 15 minutes of recorded actions between the two tours. To record a tour: Click the Start Recording button. The system prompts you to overwrite the existing tour. Click Yes to overwrite the existing tour movements. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 78: Diagnostics

    Click a scene number below the PTZ controls on the View Control tab. Use the keypad and the Show Shot button on the Aux Control tab. To define a preposition tour: Create the individual scenes. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 79: Sectors

    If you connect via Web browser, you must activate the audio transmission on the Livepage Functions page (see The Livepage, page 52). For other connections, the transmission depends on the audio settings of the respective system. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 80: Pixel Counter

    It is also possible to let the VRM Video Recording Manager Control all recording when accessing an iSCSI system. This is an external program for configuring recording tasks for video servers. For further information please contact your local customer service at Bosch Security Systems, Inc.
  • Page 81 You can deactivate any storage medium from the Managed storage media list. It is then no longer used for recordings. Click a storage medium in the Managed storage media list to select it. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 82: Recording Profiles

    You can select the encoder profile to be used for recording during the post-alarm time (see Encoder Profile, page 70). The Standard profile option adopts the selection at the top of the page. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 83: Retention Time

    Use the right mouse button to deselect any of the intervals. Click the Select All button to link all time intervals to the selected profile. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 84: Recording Status

    AutoDome Junior HD will connect in sequence in the event of an alarm, until a connection is made. Connect on alarm Select On so that the camera automatically connects to a predefined IP address in the event of an alarm. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 85 VIDOS or the Bosch Video Management System, you can store a general password here. The AutoDome Junior HD can use this general password to connect to all remote stations protected with the same password.
  • Page 86: Vca

    Select a VCA configuration and make the required settings. If necessary, click the Default button to return all settings to their default values. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 87 Notice! Additional analysis algorithms with comprehensive functions such as IVMD and IVA are available from the Bosch Security Systems Web site. If you select one of these algorithms, you can set the corresponding parameters here directly. You can find information on this in the relevant documents on the product CD supplied.
  • Page 88 Sensitivity Notice! This and the following parameter are only accessible if the reference check is activated. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 89 Left-click the fields to be activated. Activated fields are marked yellow. If necessary, click Select All to select the entire video frame for monitoring. Right-click any fields you wish to deactivate. Click OK to save the configuration. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 90: Audio Alarm

    The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the Vidos and the Bosch Video Management Systems programs. Enter a unique and clear name here. Furthermore, in the Forensic Search program, you can use the name as a filter option for quick search through the recordings.
  • Page 91: Alarm Task Editor

    The AutoDome Junior HD features an alarm rule engine. In its simplest form, an alarm rule can define which input(s) activate which output(s). Basically, an alarm rule allows you to customize an AutoDome Junior HD to automatically respond to different alarm inputs. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 92: Advanced Mode: Interfaces

    Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player programs being unable to play back the recording. 12.47 Relay You can configure the switching behavior of the relay outputs. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 93: Advanced Mode: Network

    Automatic IP assignment If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the camera. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 94 | Configuring the AutoDome Junior HD AutoDome Junior HD Series Certain applications (Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.
  • Page 95: Advanced

    Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot. Make the desired changes. Click the Set and Reboot button. The AutoDome Junior HD is rebooted and the changed settings are activated. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 96 Select the port for TCP communication. Select Off to deactivate the TCP metadata function. Sender IP Address Enter the IP address of the TCP metadata sender here. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 97: Multicast

    Port Assign a different port to each data stream if there are simultaneous data streams at the same multicast address. Enter the port address of the required stream here. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 98: Ftp Posting

    A special license, with which you will receive a corresponding activation key, is required to encrypt user data. You can enter the activation key to release the function on the Licenses page (see Licenses, page 100). 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 99: Advanced Mode: Service

    Once all files have been successfully uploaded, the unit must be rebooted. In the address bar of your browser, enter /reset after the IP address of the camera (for example 192.168.0.10/reset). The new SSL certificate is valid. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 100: Licenses

    You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 101: Keyboard Commands By Number

    Off- Stop recording On/Off 102 Record Tour B On – start recording Off- Stop recording * denotes a command applicable to the AutoDome Junior HD PTZ and Fixed cameras. Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 102: Troubleshooting

    Set the synchronization mode to INT.NTSC Model power frequency in LL mode: 60 Hz. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 103: Autodome Junior Operation And Control

    Select either 50 or 60 Hz from the Frequency pull-down list. 14.2 LED Diagnostics Use the following illustration to identify the LEDs (note the position of the three screws to align your camera): Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 104 No network activity Network Link Link is active Link failure Bi-color LED Power/IP Board Green On IP board is running Green/Red Red On IP board is booting 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 105 AutoDome Junior HD Series Troubleshooting | en No power to the IP board Green Flashing IP board is transmitting video Red Flashing IP board is resetting Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 106: Preventive Maintenance

    Do not scrape the bubble with razor blades or other sharp instruments. – Do not use Benzene, Gasoline, Acetone, or Carbon Tetrachloride on the bubble. – Do not clean bubbles in direct sunlight or on very hot days. 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 107: Bvip Firmware Updates

    TCP/IP network. An AutoDome IP and HD also allows an operator to update the BVIP firmware via the TCP/IP network. The latest BVIP firmware is available on the Bosch Security Systems Web site. To download the service pack from the Web, navigate to www.boschsecurity.us, click the CCTV link, then click Cameras, PTZ and navigate to the product page for the an AutoDome IP and HD .
  • Page 108: Index

    61 DHCP server, 63 DirectX;software DirectX, 48 display stamping, 52, 67 drywall ceiling;installing drywall ceiling;preparing:drywall ceiling, 16 dual Streaming, 70 dual streaming;IP dual streaming, 47 DVR;devices DVR, 14 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 109 JPEG posting interval, 98 JPEG;files JPEG, 48 keyboard commands, 56 keyboard commands;commands keyboard;displaying:on-screen menus;Aux On;commands:Aux On;Aux Off;commands:Aux Off;Set Shot;commands:Set Shot;Show Shot command;commands:Show Shot;keyboard commands:Aux On;keyboard commands:Aux Off command;command numbers, 56 keypad, 56 Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 110 63, 93, 95 reflections of light, 88 network settings page;AutoDome Replay, 59 IP:network settings page;configuring:IP router, 98 AutoDome:network settings, 50 non-supervised alarms;alarm inputs non-supervised, 42 number of connections, 53 2014.11 | 6.1 | F.01U.275.803 Operation Manual Bosch Security Systems, Inc.
  • Page 111 IP address, 67 time server protocol, 67 time signal, 62, 67 time zone, 66 TLS, 95 tour guard, 77 recorded, 77 transmission protocol, 85, 94 traps, 96 TTL, 98 Bosch Security Systems, Inc. Operation Manual 2014.11 | 6.1 | F.01U.275.803...
  • Page 114 Bosch Security Systems, Inc. Bosch Sicherheitssysteme GmbH 850 Greenfield Road Robert-Bosch-Ring 5 Lancaster, PA, 17601 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Security Systems, Inc., 2014...

Table of Contents